Related Experiment Video
Updated: Aug 14, 2025

In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
Successful Desensitization to the Radiocontrast Material Iohexol (Omnipaque™)
Abeer Saad1, Asmaa S Mahdi1, Iman Nasr1
1Medicine, The Royal Hospital, Muscat, OMN.
Abstract:
Adverse reactions to radiocontrast media (RCM) are rare and occur predominantly in association with intravenous administration but may also occur with intra-arterial and nonvascular injections (e.g., retrograde pyelography, intra-articular injections) of RCM. This article reports the case of a 52-year-old lady who was known to have amyloidosis secondary to rheumatoid arthritis and was on regular renal replacement therapy. She was under follow-up for regular angioplasties to manage the central vein stenosis that was affecting her right brachiocephalic arteriovenous fistula (AVF) and was referred to our Immunology service when she developed an allergic reaction after her AVF angioplasty (central venoplasty). Despite being dialysed immediately post-angioplasty, she complained of skin rash and itching with hoarseness of voice that developed almost six to eight hours post-angioplasty. We decided to arrange the iodinated non-ionic iso-osmolar contrast agent iodixanol (Visipaque™) for her instead, as it is known to be better tolerated in patients with reactions to Omnipaque™ due to its lower osmolarity as compared to Omnipaque™. However, since it was the first time to request this contrast in our hospital, it was not possible due to logistical reasons. It was necessary that our patient continued to undergo angioplasty every three months, however, she was developing more severe and earlier symptoms with each subsequent exposure to the radiocontrast medium. After her latest reaction of generalized itching and angioedema with shortness of breath during the procedure despite premedication, it was decided for her to undergo desensitization to Omnipaque™. In the absence of a published protocol for this, we used a protocol used for desensitization to Visipaque™. She showed an excellent response and completed her remaining angioplasties until Visipaque™ became available. Hence, desensitization to Omnipaque™ using the published protocol to Visipaque™ is likely to help patients allergic to Omnipaque™ or where Visipaque™ is not available or non-affordable in low/middle-income countries.
More Related Videos
08:41Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease
Published on: March 24, 2023
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies VII: Vascular Imaging