Related Experiment Video
Updated: Aug 14, 2025

Modified Experimental Conditions for Noise-Induced Hearing Loss in Mice and Assessment of Hearing Function and Outer Hair Cell Damage
Published on: February 10, 2023
Effectiveness of Kurtosis-Adjusted Cumulative Noise Exposure in Assessing Occupational Hearing Loss Associated With
Jiarui Xin1,2, Zhihao Shi3, Peiyi Qian1
1National Institute of Occupational Health and Poison Control, Chinese Center for Disease Control and Prevention, Beijing, China.
Objectives:
Occupational noise-induced hearing loss (NIHL) is one of the most prevalent occupational diseases worldwide. Few studies have been reported on applying kurtosis-adjusted noise energy (e.g., kurtosis-adjusted cumulative noise exposure, CNE-K) as a joint indicator for assessing NIHL. This study aimed to analyze the effectiveness of CNE-K in assessing occupational hearing loss associated with complex noise in typical manufacturing industries.
Design:
A cross-sectional survey of 1404 Chinese manufacturing workers from typical manufacturing industries was conducted. General demographic characteristics, noise exposure data, and noise-induced permanent threshold shifts (NIPTS) at 3, 4, and 6 kHz (NIPTS 346 ) were collected and analyzed. The role of kurtosis in high-frequency noise-induced hearing loss (HFNIHL) was also analyzed. The degree of overlap of the two logistic curves (i.e., between complex noise CNE-K and HFNIHL%, and between Gaussian noise CNE and HFNIHL%) was used to evaluate the effectiveness of CNE-K, using a stratified analysis based on age, sex, industry, or job type.
Results:
The binary logistic regression analysis showed that in addition to age, sex, exposure duration, and Eight-hour Continuous Equivalent A-weighted Sound Pressure Level (L Aeq,8h ), kurtosis was a key factor influencing HFNIHL% in workers (odds ratio = 1.18, p < 0.05), and its odds ratio increased with an increase in kurtosis value. Multiple linear regression analysis demonstrated that the contribution of kurtosis to NIPTS 346 was second to L Aeq,8h . Complex noise led to a higher risk of NIHL than Gaussian noise at frequencies of 3, 4, 6, and 8 kHz after adjusting for age, sex, and CNE ( p < 0.05). As kurtosis increased, the notch in the audiogram became deeper, and the frequency at which the notch began to deepen shifted from 3 to 1 kHz. The logistic curve between complex noise CNE-K and HFNIHL% nearly overlapped with that between Gaussian noise CNE and HFNIHL%, and the average difference in HFNIHL% between the two curves decreased from 8.1 to 0.4%. Moreover, the decrease of average difference in HFNIHL% between the two logistic curves was evident in several subgroups, such as male workers, aged <30 and 30 to 50 years, furniture and woodworking industries and gunning and nailing job types with relatively high kurtosis values.
Conclusions:
Kurtosis, as an indirect metric of noise temporal structure, was an important risk factor for occupational NIHL. Kurtosis-adjusted CNE metric could be more effective than CNE alone in assessing occupational hearing loss risk associated with complex noise.