Related Experiment Video
Updated: Aug 14, 2025

Bacterial Detection & Identification Using Electrochemical Sensors
Published on: April 23, 2013
Sensitive electrochemical immunosensor via amide hydrolysis by DT-diaphorase combined with five redox-cycling
Putu Udiyani Prayikaputri1, Seonhwa Park1, Seonghye Kim1
1Department of Chemistry and Chemistry Institute for Functional Materials, Pusan National University, Busan, 46241, Republic of Korea.
Abstract:
Amide hydrolysis using enzyme labels, such as proteases, occurs at a slower rate than phosphoester and carboxyl ester hydrolysis. Thus, it is not very useful for obtaining high signal amplification in biosensors. However, amide hydrolysis is less sensitive to nonenzymatic spontaneous hydrolysis, allowing for lower background levels. Herein, we report that amide hydrolysis by DT-diaphorase (DT-D) occurs rapidly and that its combination with five redox-cycling reactions allows for the development of a highly sensitive electrochemical immunosensor. DT-D rapidly generates ortho-aminohydroxy-naphthalene (oAN) from its amide substrate via amide hydrolysis, which not even trypsin, a highly catalytic protease, can achieve. NADH, which is required for amide hydrolysis, advantageously acts as a reducing agent for rapid electrooxidation-based redox-cycling reactions. In the presence of oAN, DT-D, and NADH, two redox-cycling reactions rapidly occur. In the additional presence of an electron mediator, Ru(NH3)63+ [Ru(III)], three more redox-cycling reactions occur because Ru(III) reacts rapidly with oAN and DT-D. Although the O2-related redox-cycling reactions and redox reaction decrease electrochemical signals, this signal-decreasing effect is not significant in air-saturated solutions. The slow electrooxidation of NADH at an indium tin oxide electrode and sluggish reaction between NADH and Ru(III) allow for low electrochemical backgrounds. When the developed signal amplification scheme is tested for the sandwich-type electrochemical detection of parathyroid hormone (PTH), a detection limit of ∼1 pg/mL is obtained. The detection method is highly sensitive and can accurately measure PTH in serum samples.
More Related Videos
13:15Fabrication of Electrochemical-DNA Biosensors for the Reagentless Detection of Nucleic Acids, Proteins and Small Molecules
Published on: June 1, 2011
07:07Synthetic Methodology for Asymmetric Ferrocene Derived Bio-conjugate Systems via Solid Phase Resin-based Methodology
Published on: March 12, 2015
Related Concept Videos
Amperometry: Overview
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or...