Related Experiment Video
Updated: Aug 14, 2025

Agarose-based Tissue Mimicking Optical Phantoms for Diffuse Reflectance Spectroscopy
Published on: August 22, 2018
Specific absorbed fractions of electrons and photons for Digimouse voxelized phantom using GATE/GEANT4 Monte-Carlo
Khaoula Laazouzi1, Hamid Boukhal1, El Mahjoub Chakir2
1Laboratory of Radiations and Nuclear Systems, Faculty of Sciences, University Abdelmalek Essaadi, Tetouan, Morocco.
Abstract:
Knowledge of SAF at different energies is crucial for internal dosimetry. For this purpose, a set of calculated SAF values for a mouse voxelized phantom's selected organs are presented below. Values of SAF were calculated for mono-energetic photons and electrons with energy varying from 10 keV to 4 MeV using the Monte Carlo simulation via GATE/GEANT4 code (GEANT4 Application for Emission Tomography). The heart, liver, lungs, kidneys, and spleen were considered as the source organs from which the particles were released. Then, the estimated results were compared to those calculated in a previous study using EGS4 code. It is indicated that the obtained results are in good agreement with the reference values for all energies of photons and electrons, with discrepancies less than 9% and 5% for self-irradiation and cross-irradiation, respectively.
More Related Videos
10:23Author Spotlight: A Machine-Vision Approach to Transmission Electron Microscopy Workflows, Results Analysis and Data Management
Published on: June 23, 2023
12:24Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers
Published on: July 17, 2012