Impact of keratoprosthesis implantation on retinal and visual pathway function assessed by electrophysiological
Luzia Diegues Silva1, Adriana Berezovsky1, Solange Rios Salomão1
1Departamento de Oftalmologia E Ciências Visuais, Escola Paulista de Medicina, Universidade Federal de São Paulo - UNIFESP, Rua Botucatu, 806, SP, 04023-062, São Paulo, Brazil.
Purpose:
To investigate the impact of Boston Type I Keratoprosthesis (BI-Kpro) implantation on retinal and visual pathway function, respectively, assessed by full-field electroretinography (ERG) and visually evoked potentials (VEPs).
Methods:
This is a prospective interventional longitudinal study, and patients with BI-Kpro implantation were assessed preoperatively and at 3 and 12 months after surgery. ERG, flash, and pattern-reversal VEPs (15' and 60' checks) along with visual acuity (VA) were performed.
Results:
A total of 13 patients (24 to 88 years of age) were included. Mean baseline VA (logMAR) improved from 2.30 to 1.04 at 3 months and to 1.00 at 12 months. Flash VEPs were normal in 6 (46%) patients and in 10 (77%) patients at the 12-month follow-up. PVEP was non-detectable in all patients preoperatively for both check sizes. For 15' check size, 6 (46%) patients showed responses after 3 and 12 months except for 1 patient with normal responses at 12 months with the remaining non-detectable. For 60' checks, 11 (85%) patients had responses 3 months after surgery with only 9 (70%) showing responses at 12 months. Abnormal full-field ERGs were found in all patients preoperatively. Amplitude improvement was found in 10 (77%) patients from baseline to 3 months and in 8 (62%) patients from the 3- to the 12-month follow-up.
Conclusions:
In this small cohort of patients with BI-Kpro implantation, a remarkable improvement on visual function quantitatively assessed by electrophysiological testing was found in the majority of cases. Visual electrophysiological testing can contribute to objectively assess functional outcomes in this population.