Investigating thrombin-loaded fibrin in whole blood clot microfluidic assay via fluorogenic peptide
Jennifer Crossen1, Kaushik N Shankar1, Scott L Diamond1
1Institute for Medicine and Engineering, Department of Chemical and Biomolecular Engineering, 1024 Vagelos Research Laboratory, University of Pennsylvania, Philadelphia, PA 19104.
Abstract:
During clotting under flow, thrombin rapidly generates fibrin, whereas fibrin potently sequesters thrombin. This co-regulation was studied using microfluidic whole blood clotting on collagen/tissue factor, followed by buffer wash, and a start/stop cycling flow assay using the thrombin fluorogenic substrate, Boc-Val-Pro-Arg-AMC. After 3 min of clotting (100 s-1) and 5 min of buffer wash, non-elutable thrombin activity was easily detected during cycles of flow cessation. Non-elutable thrombin was similarly detected in plasma clots or arterial whole blood clots (1000 s-1). This thrombin activity was ablated by Phe-Pro-Arg-chloromethylketone (PPACK), apixaban, or Gly-Pro-Arg-Pro to inhibit fibrin. Reaction-diffusion simulations predicted 108 nM thrombin within the clot. Heparin addition to the start/stop assay had little effect on fibrin-bound thrombin, whereas addition of heparin-antithrombin (AT) required over 6 min to inhibit the thrombin, indicating a substantial diffusion limitation. In contrast, heparin-AT rapidly inhibited thrombin within microfluidic plasma clots, indicating marked differences in fibrin structure and functionality between plasma clots and whole blood clots. Addition of GPVI-Fab to blood before venous or arterial clotting (200 or 1000 s-1) markedly reduced fibrin-bound thrombin, whereas GPVI-Fab addition after 90 s of clotting had no effect. Perfusion of AF647-fibrinogen over washed fluorescein isothiocyanate (FITC)-fibrin clots resulted in an intense red layer around, but not within, the original FITC-fibrin. Similarly, introduction of plasma/AF647-fibrinogen generated substantial red fibrin masses that did not penetrate the original green clots, demonstrating that fibrin cannot be re-clotted with fibrinogen. Overall, thrombin within fibrin is non-elutable, easily accessed by peptides, slowly accessed by average-sized proteins (heparin/AT), and not accessible to fresh fibrinogen.
More Related Videos
09:38A Microfluidic Flow Chamber Model for Platelet Transfusion and Hemostasis Measures Platelet Deposition and Fibrin Formation in Real-time
Published on: February 14, 2017
13:08Measurement of Factor V Activity in Human Plasma Using a Microplate Coagulation Assay
Published on: September 9, 2012