Related Experiment Video
Updated: Aug 14, 2025

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Highly Integrated μGC Based on a Multisensing Progressive Cellular Architecture with a Valveless Sample Inlet
Weilin Liao1, Declan Winship1, Irene Lara-Ibeas1
1Department of Electrical Engineering and Computer Science, Center for Wireless Integrated MicroSensing and Systems (WIMS2), University of Michigan, Ann Arbor, Michigan 48109, United States.
Abstract:
Microscale gas chromatographs (μGCs) promise in-field analysis of volatile organic compounds (VOCs) in environmental and industrial monitoring, healthcare, and homeland security applications. As a step toward addressing challenges with performance and manufacturability, this study reports a highly integrated monolithic chip implementing a multisensing progressive cellular architecture. This architecture incorporates three μGC cells that are customized for different ranges of analyte volatility; each cell includes a preconcentrator and separation column, two complementary capacitive detectors, and a photoionization detector (PID). An on-chip carrier gas filter scrubs ambient air for the analysis. The monolithic chip, with all 16 components, is 40.3 × 55.7 mm2 in footprint. To accommodate surface adsorptive and low-volatility analytes, the architecture eliminates the commonly used inlet valve, eliminating the need for chemically inactive surfaces in the valves and pumps, allowing the use of standard parts. Representative analysis is demonstrated from a nonpolar 14-analyte mixture, a polar 12-analyte mixture, and a 3-phosphonate ester mixture, covering a wide vapor pressure range (0.005-68.5 kPa) and dielectric constant range (1.8-23.2). The three types of detectors show highly complementary responses. Quantitative analysis is shown in the tens to hundreds ppb range. With 200 mL samples, the projected detection limits reach 0.12-4.7 ppb. Limited tests performed at 80% humidity showed that the analytes with vapor pressures <12 kPa were unaffected. A typical full run takes 28 min and consumes 2.3 kJ energy for the fluidic elements (excluding electronics). By eliminating chip-to-chip fluidic interconnections and requiring just one custom-fabricated element, this work presents a path toward high-performance and highly manufacturable μGCs.
More Related Videos
07:55Integrated Cell Manipulation Platform Coupled with the Single-probe for Mass Spectrometry Analysis of Drugs and Metabolites in Single Suspension Cells
Published on: June 21, 2019
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...