Related Experiment Video
Updated: Aug 14, 2025

Murine Endoscopy for In Vivo Multimodal Imaging of Carcinogenesis and Assessment of Intestinal Wound Healing and Inflammation
Published on: August 26, 2014
Comparison of adenoma detection rate between high-definition colonoscopes with different fields of view: 170 degrees
Sang Yi Moon1, Jong Yoon Lee, Jong Hoon Lee
1Department of Internal Medicine, Dong-A University College of Medicine, Busan, South Korea.
Abstract:
In newer generation colonoscopes, the field of view (FOV) varies approximately between 170° and 140°, depending on the type of colonoscopy. To the best of our knowledge, no study has investigated whether the visual field difference of the colonoscope affects quality indicators, such as the adenoma detection rate (ADR), without using additional devices to expand the FOV in colonoscopes with the same resolution. This study aimed to investigate the difference in quality indicators, such as ADR, between 170° and 140° FOV in colonoscopes with the same high-definition resolution. We retrospectively analyzed the medical records of patients who underwent screening or surveillance colonoscopy at the Dong-A University Hospital in Busan, South Korea, between March 2021 and February 2022. We calculated the overall ADR ratios for patients who underwent colonoscopy with 140° and 170° FOV. Polyp detection rate (PDR), sessile serrated PDR, and advanced neoplasia detection rate were calculated for each group. Factors associated with adenoma detection were identified using a logistical regression analysis. A total of 1711 patients were included in the study (838 patients in the 170° group and 873 patients in the 140° group). ADR (43.79 vs 41.92%, P = .434) did not significantly differ between the 2 groups. The generational differences were not statistically significant either for PDR (56.44 vs 53.49%, P = .220), sessile serrated PDR (1.19 vs 0.92%, P = .575), or advanced neoplasia detection rate (5.00 vs 4.58%, P = .735). Multivariate regression analysis revealed that, age, male sex, and long withdrawal time were the most significant factors affecting adenoma detection. This study revealed that there were no differences in ADR while employing high definition colonoscopes with a 170° FOV and a 140° FOV.
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures III: Video Capsule Endoscopy
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...

