In-vivo high-speed biomechanical imaging of the cornea using Corvis ST and digital image correlation
Bo Wang1, Lanting Yang2, Jiaxuan Cheng2
1State Key Laboratory of Structural Analysis for Industrial Equipment, Department of Engineering Mechanics, Dalian University of Technology, Dalian, 116023, PR China; International Research Center for Computational Mechanics, Dalian University of Technology, Dalian, 116023, PR China; Ningbo Institute of Dalian University of Technology, Ningbo, 315016, PR China; DUT-BSU Joint Institute, Dalian University of Technology, 116023, PR China.
Abstract:
In-vivo corneal biomechanical characterization has gained significant clinical relevance in ophthalmology, especially in the early diagnosis of eye disorders and diseases (e.g. keratoconus). In clinical medicine, the air-puff-based tonometers such as Ocular Response Analyzer (ORA) and Corvis ST have been used in the in-vivo biomechanical testing. In the test, the high-speed dynamic deformation of the cornea under air-puff excitation is analyzed to identify the abnormities in the morphological and biomechanical properties of the cornea. While most existing measurements reflect the overall corneal biomechanical properties, in-vivo high-speed strain and strain rate fields at the tissue level have not been assessed. In this study, 20 subjects were classified into two different groups: the normal (NORM, N = 10) group and the keratoconus (KC, N = 10) group. Image sequences of the horizontal cross-section of the human cornea under air puff were captured by the Corvis ST tonometer. The macroscale mechanical response of the cornea was determined through image analysis. The high-speed evolution of full-field corneal displacement, strain, velocity, and strain rate was reconstructed using the incremental digital image correlation (DIC) approach. Differences in the parameters between the NORM and KC groups were statistically analyzed and compared. Statistical results indicated that compared with the NORM group, the KC corneas absorbed more energy (KC: 8.98 ± 2.76 mN mm; NORM: 4.79 ± 0.62 mN mm; p-value <0.001) with smaller tangent stiffness (KC: 22.49 ± 2.62 mN/mm; NORM: 24.52 ± 3.20 mN/mm; p-value = 0.15) and larger maximum deflection (KC: 0.99 ± 0.07 mN/mm; NORM: 0.92 ± 0.06 mN/mm; p-value <0.05) on the macro scale. Further, we also observed that The maximum displacement (KC: 1.17 ± 0.06 mm; NORM: 1.06 ± 0.07 mm; p-value <0.005), velocity (KC: 236 ± 29 mm/s; NORM: 203 ± 17 mm/s; p-value <0.01), shear strain (KC: 24.43 ± 2.59%; NORM: 20.26 ± 1.54%; p-value <0.001), and shear strain rate (KC: 69.74 ± 11.99 s-1; NORM: 54.84 ± 3.03 s-1; p-value <0.005) in the KC group significantly increased at the tissue level. This is the first time that the incremental DIC method was applied to the in-vivo high-speed corneal deformation measurement in combination with the Corvis ST tonometer. Through the image registration using incremental DIC analysis, spatiotemporal dynamic strain/strain rate maps of the cornea can be estimated at the tissue level. This is constructive for the clinical recognition and diagnosis of keratoconus at a more underlying level.
More Related Videos
11:29Corneal Confocal Microscopy: A Novel Non-invasive Technique to Quantify Small Fibre Pathology in Peripheral Neuropathies
Published on: January 3, 2011
06:19In Vivo Imaging of Cx3cr1gfp/gfp Reporter Mice with Spectral-domain Optical Coherence Tomography and Scanning Laser Ophthalmoscopy
Published on: November 11, 2017
Related Concept Videos
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Confocal Fluorescence Microscopy