Related Experiment Video
Updated: Aug 14, 2025

Surgical Treatment of an Endolymphatic Sac Tumor
Published on: May 26, 2023
CT evaluation of unilateral pulsatile tinnitus with jugular bulb wall dehiscence
Chihang Dai1, Pengfei Zhao2, Heyu Ding1
1Department of Radiology, Beijing Friendship Hospital, Capital Medical University, No. 95, Yongan Road, Xicheng District, Beijing, 100050, China.
Objectives:
To investigate the imaging features of unilateral pulsatile tinnitus (PT) with jugular bulb wall dehiscence (JBWD).
Methods:
Computerized tomography angiography images of unilateral PT patients were reviewed between 2019 and 2021. Thirty-one symptomatic JBWD patients without sigmoid sinus wall dehiscence (SSWD) were included. Thirty-eight patients with SSWD were used as the control group. The prevalence of JBWD was calculated. The area and height of the jugular bulb, the extent of dehiscence, the presence of jugular bulb diverticulum, posterior condylar emissary vein (PCEV), oblique occipital sinus (OOS), venous outflow laterality (VOL), the degree of transverse sinus stenosis (TSS), and the pituitary height to sella turcica ratio were compared between the two groups.
Results:
The prevalence of JBWD was 12.1%, and JBWD was established as a causative diagnosis in 5.0% of unilateral PT patients. There were no statistical differences in the gender, symptomatic side, or VOL between the two groups. The area of the jugular bulb was larger and the height was higher (parea < 0.001, pheight = 0.005). The prevalence of jugular bulb diverticulum was higher in the JBWD group (p = 0.002). The degree of symptomatic TSS was less severe (p < 0.001), and the prevalence of bilateral TSS was lower in the JBWD group (p < 0.001). The pituitary height to sella turcica ratio was greater (p = 0.004), the prevalence of PCEV (p = 0.014) was lower, and OOS (p = 0.015) was greater in the JBWD group.
Conclusions:
The correlating factors of PT with JBWD and PT with SSWD are significantly different. These findings can further facilitate early and efficient PT treatment.
Key Points:
• The incidence of jugular bulb dehiscence (JBWD) accounted for approximately 12.1% in pulsatile tinnitus (PT) patients, and JBWD was established as a causative diagnosis in 5.0% of PT patients. • PT required large blood flows and abnormal flow patterns, whether in JBWD or sigmoid sinus wall dehiscence groups. • JBWD causing PT has some unique characteristic findings on CT.
More Related Videos
12:21The Mouse Round-window Approach for Ototoxic Agent Delivery: A Rapid and Reliable Technique for Inducing Cochlear Cell Degeneration
Published on: November 26, 2015
07:06Endaural Endoscopic Atticoantrotomy Retrograde Mastoidectomy using a Constant Suction Bone-drilling Technique
Published on: May 23, 2021
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Mitral Regurgitation II: Clinical Features and Diagnostic Tests
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Mitral Stenosis II: Clinical features and Diagnostic Tests
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Mitral Regurgitation I: Introduction