Base-apex electrocardiographic examination in healthy cows of Chianina breed
Maria Cicogna1, Piero Boni2, Tommaso Frigo3
1Department of Veterinary Medicine, University of Perugia, Perugia, Italy.
Background:
The electrocardiography is a useful diagnostic tool for the characterization of the cardiac rhythm in veterinary medicine. In cattle, standard electrocardiographic (ECG) exam is commonly performed using the base-apex lead system and reference values for ECG parameters have been reported for different breeds of cows. However, no ECG studies have been conducted in Chianina breed.
Aim:
To determine the feasibility and normal values for standard base-apex electrocardiography in clinically healthy Chianina cows.
Methods:
A standard base-apex ECG examination was acquired in 45 Chianina cows. All the cows were considered healthy based on history and physical examination. The following ECG parameters were evaluated: heart rate (HR); morphology of P wave, QRS complex, and T wave; amplitude and duration of P wave, QRS complex, and T wave; duration of PR and QT intervals. Correlations between ECG parameters and clinical variables were analyzed.
Results:
Morphology of the ECG waves/complexes and values for all ECG parameters recorded in the 45 clinically healthy Chianina cows were reported. Correlations between HR and body weight (BW), QT interval and BW, QT interval and HR, P wave amplitude and HR, PR interval and HR, R wave amplitude and age were observed. Statistical difference between HR in pregnant and non-pregnant cows was also found.
Conclusion:
Base-apex electrocardiogram is suitable for monitoring heart rhythm in clinically healthy Chianina cows and reference values for main ECG parameters have been reported for this breed. This study can be a useful contribution to the literature, updating current knowledge on the electrocardiography in cattle.
More Related Videos
02:47Author Spotlight: Exercise Test for Evaluation of the Functional Efficacy of the Pig Cardiovascular System
Published on: May 12, 2023
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....