Monitoring of ultra- and diafiltration processes by Kalman-filtered Raman measurements
Laura Rolinger1,2, Jürgen Hubbuch1, Matthias Rüdt3,4
1Institute of Engineering in Life Sciences, Section IV: Biomolecular Separation Engineering, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany.
Raman spectroscopy combined with an Extended Kalman Filter (EKF) improves monitoring of biopharmaceutical Ultrafiltration/Diafiltration (UF/DF) processes. This approach enhances excipient monitoring and enables adaptive process control for automation.
Area of Science:
- Biopharmaceutical Manufacturing
- Process Analytical Technology (PAT)
- Spectroscopy
Background:
- Ultrafiltration/Diafiltration (UF/DF) is critical in biopharmaceutical production.
- Real-time monitoring of protein and excipient concentrations is essential for process automation and control.
- Existing methods like UV and IR spectroscopy have limitations in monitoring low concentrations.
Purpose of the Study:
- To evaluate the combination of Raman spectroscopy and an Extended Kalman Filter (EKF) for monitoring UF/DF processes.
- To assess the performance of this combined approach for protein and excipient concentration monitoring.
- To demonstrate the potential for process automation through adaptive control.
Main Methods:
- Utilized Raman spectroscopy for in-line measurement of protein and excipient concentrations.
- Integrated Raman measurements with a semi-mechanistic model using an Extended Kalman Filter (EKF).
- Conducted three case studies to validate the combined approach, comparing it with density and VP-UV measurements.
Main Results:
- Kalman-filtered Raman measurements showed improved sensitivity for excipient monitoring compared to density measurements.
- Raman spectroscopy offered faster measurement speeds than VP-UV but with slightly lower protein prediction accuracy.
- Protein concentration monitoring via Raman relied on background signal changes, indicating potential batch variability concerns.
Conclusions:
- The combination of Raman spectroscopy and EKF is a promising tool for monitoring UF/DF steps.
- This integrated approach can enhance process automation by enabling adaptive process control.
- Further development is needed to address batch variability in Raman-based protein concentration measurements.
More Related Videos
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...