Related Experiment Video
Updated: Aug 14, 2025

08:19
Hollow Microneedle-based Sensor for Multiplexed Transdermal Electrochemical Sensing
Published on: June 1, 2012
14.5K
Carbendazim trace analysis in different samples by using nanostructured modified carbon paste electrode as
Abbasali Kasaeinasab1,2, Hassan Asilian Mahabadi1, Seyed Jamaleddin Shahtaheri3
1Department of Occupational Health Engineering, School of Medical Sciences, Tarbiat Modares University, Tehran, Iran.
Plos One
|January 18, 2023
Summary
A novel sensor combining molecular imprinted polymer and multiwalled carbon nanotubes effectively detects the fungicide carbendazim (CBZ). This highly sensitive and selective method is suitable for analyzing CBZ in various environmental and biological samples.
Area of Science:
- Electrochemistry
- Materials Science
- Environmental Science
Background:
- Carbendazim (CBZ) is a widely used fungicide in agriculture, veterinary medicine, and forestry.
- Accurate and sensitive detection methods are crucial for monitoring CBZ levels in various matrices.
- Existing detection methods may lack selectivity or require complex sample preparation.
Purpose of the Study:
- To develop a novel electrochemical sensor for the sensitive and selective detection of carbendazim (CBZ).
- To utilize molecularly imprinted polymer (MIP) combined with multiwalled carbon nanotubes (MWCNTs) as modifiers for a carbon paste electrode.
- To evaluate the sensor's performance in detecting CBZ in diverse samples like water, fruit, agricultural wastewater, and urine.
Main Methods:
- Synthesis of molecularly imprinted nano-size polymer.
- Modification of carbon paste electrode with MIP and multiwalled carbon nanotubes (MWCNTs).
- Electrochemical detection of carbendazim using square-wave voltammetry.
- Investigation of interferences from common ions and pesticides.
Main Results:
- The MIP-MWCNT modified electrode exhibited significantly enhanced peak current and electrocatalytic activity for CBZ detection.
- The sensor demonstrated a wide linear range from 1 × 10⁻¹⁰ to 5 × 10⁻⁸ mol L⁻¹.
- A low detection limit of 0.2 × 10⁻¹⁰ mol L⁻¹ and a relative standard deviation of 2.07% were achieved.
Conclusions:
- The developed sensor offers high selectivity and sensitivity for carbendazim determination.
- The MIP-MWCNT modified carbon paste electrode provides a simple, rapid, and effective platform for CBZ analysis.
- This sensor is a promising tool for monitoring carbendazim in complex real-world samples.