Arthroscopic treatment of unstable scaphoid fracture and nonunion with two headless compression screws and distal radius bone graft
Related Experiment Video
Updated: Aug 14, 2025

Novel Triple-Loop Technique for Suturing TFCC Injuries without Transosseous Tunnel
Published on: May 23, 2025
Cong Cheng1, Zongyuan Jiang1, Haoran Sun1
1Department of Hand Surgery, Affiliated Longhua People's Hospital, Southern Medical University, Shenzhen, 518000, China.
Background:
The treatment of unstable scaphoid fracture and nonunion remains a challenging problem for hand surgeons. Minimally invasive treatment has become the preferred method of treatment.
Purpose:
This study introduces the arthroscopic technique with two headless compression screws (HCS) fixation and distal radius bone grafting for the treatment of unstable scaphoid fracture and nonunion, aiming to evaluate its clinical and radiological outcomes.
Methods:
It was a retrospective study. From January 2019 to February 2021, a total of 23 patients were included in the current study. Among them, 13 patients with unstable scaphoid fracture underwent arthroscopic treatment with two HCS; 10 patients with scaphoid nonunion underwent arthroscopic treatment with two HCS and a distal radius bone graft. The range of motion of the wrist, visual analog scale (VAS), grip strength, the Modified Mayo Wrist Score (MMWS), the Patient-Rated Wrist Evaluation (PRWE) score, and the Disability of the Arm, Shoulder and Hand (DASH) score were collected at preoperatively and the final follow-up. A computed tomography scan of the wrist was performed on each patient to analyze for union and postoperative osteoarthritis during the follow-up period.
Results:
Significant improvement was only observed in wrist extension. Clinical outcomes including grip strength, VAS pain score, MMWS, PRWE score, and DASH score were significantly improved at the final follow-up. In the subgroup analysis, both patients stabilized with either two HCS or a distal radius bone graft and two HCS have improved clinical outcomes after surgery, respectively. All patients achieved union. No screw fixation failure occurred, and no other postoperative complication was observed in any of the patients.
Conclusions:
The arthroscopic technique with two-HCS fixation and distal radius bone grafting is a reliable and effective technique for the treatment of unstable scaphoid fracture and nonunion, providing satisfactory union rates and clinical outcomes.
More Related Videos
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
06:41A Minimally Invasive Model to Analyze Endochondral Fracture Healing in Mice Under Standardized Biomechanical Conditions
Published on: March 22, 2018
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a...