Related Experiment Video
Updated: Aug 14, 2025

A Bedside, Single Burr Hole Approach to Multimodality Monitoring in Severe Brain Injury
Published on: March 26, 2019
Association between central venous pressure measurement and outcomes in critically ill patients with severe coma
Xin Tong1, Xin Feng2,3, Chuanzhi Duan4,5
1Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, Beijing, 100050, China.
Background:
The use of central venous pressure (CVP) measurements among (intensive care unit) ICU patients with severe coma has been questioned. This study aimed to investigate the application value of CVP in this population.
Methods:
Data stored in the ICU Collaborative Research Database (eICU-CRD) and Medical Information Mart for Intensive Care III (MIMIC-III) database were reviewed. Critically ill patients with a Glasgow Coma Scale (GCS) score of 3-8 were included. The primary outcome was the in-hospital mortality rate. The statistical approaches used included multivariable Cox regression, propensity score matching (PSM), inverse probability treatment weighting (IPTW), stabilized IPTW, and restricted cubic splines (RCS) to ensure the robustness of our findings.
Results:
In total, 7386 patients were included in the study. Early CVP measurement was independently associated with in-hospital mortality [hazard ratio, 0.63; p < 0.001] in patients with severe-to-moderate coma. This result was robust in the PSM, sIPTW, and IPTW cohorts. For all patients with CVP measurements, the RCS curves showed that the risk of in-hospital mortality increased as the initial CVP time was delayed. In addition, early CVP measurement was significantly associated with lower ICU mortality, 28-day mortality, and 365-day mortality and a significantly higher number of ventilator-free days.
Conclusion:
Early CVP measurement could improve clinical outcomes in critically ill patients with severe coma.
Related Concept Videos
Measurement of Blood Pressure
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Pre-Procedural Guidelines for Assessing Blood Pressure
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Aneurysm IV: Nursing Management
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.

