Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
Published on: May 7, 2021
Single-pixel imaging with neutrons
Yu-Hang He1, Yi-Yi Huang1, Zhi-Rong Zeng2
1Institute of Physics, Chinese Academy of Sciences, Beijing 100190, China; University of Chinese Academy of Sciences, Beijing 100049, China.
Abstract:
Neutron imaging is an invaluable tool for noninvasive analysis in many fields. However, neutron facilities are expensive and inconvenient to access, while portable sources are not strong enough to form even a static image within an acceptable time frame using traditional neutron imaging. Here we demonstrate a new scheme for single-pixel neutron imaging of real objects, with spatial and spectral resolutions of 100 μm and 0.4% at 1 Å, respectively. Low illumination down to 1000 neutron counts per frame pattern was achieved. The experimental setup is simple, inexpensive, and especially suitable for low intensity portable sources, which should greatly benefit applications in biology, material science, and industry.