Simple and Easily Interpretable Flap Monitoring Method Using a Commercial Pulse Oximeter and a Widely Used Bedside
Daisuke Atomura1,2, Sayaka Hoshino2, Takeo Osaki3
1Department of Plastic Surgery, Kobe University Hospital International Clinical Cancer Research Center, Kobe, JPN.
Abstract:
Background Various methods for monitoring after free flap surgery have been reported in the literature. Among them, pulse oximetry shows a sensitive reaction to vascular issues, and it is easy to interpret visually. However, previous reports used special equipment that was less commonly used and difficult to generalize. In this study, we used a commercial pulse oximeter and a widely used bedside patient monitor to monitor transplanted free tissue and lower extremities of healthy subjects with impaired circulation. Methods A reflectance pulse oximeter sensor was attached on the flap after free tissue transplantation. The sensor was connected to a bedside patient monitor, and the flap oxygen saturation (SpO2) levels and arterial waveforms were continuously monitored. Additionally, blood circulation disorder was induced in the lower limbs of healthy volunteers using pressure cuff inflation on the thigh, and the waveform and SpO2 levels on the pulse oximeter attached to the lower leg were monitored. Results Twenty-two patients were included in this study. No postoperative vascular issues were observed in any case. Pulse oximeters showed normal rhythmic wavelengths, and the flap SpO2 level ranged approximately >90%. The pulse oximeter waveform rapidly disappeared during arterial occlusion in the thigh pressure cuff inflation test, and the waveform flattened and the SpO2 level decreased slightly during venous congestion. Conclusion Flap monitoring using a commercially available pulse oximeter and a bedside patient monitor is a versatile, easy-to-interpret, and useful method. Changes in waveform and SpO2 levels appear during arterial and venous circulation disorders, and these changes can be differentiated.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation