Multimodal Hierarchical Imaging of Serial Sections for Finding Specific Cellular Targets within Large Volumes
Published on: March 20, 2018
Optimized detector configurations for the reconstruction of phase-contrast images in scanning transmission electron
1University of Münster (Westfälische Wilhelms-Universität Münster), Wilhelm Klemm Str. 10, 48149 Münster, Germany.
Abstract:
Using the differential phase contrast mechanism and anti-symmetric detector geometries it is possible to image distributions of electric and magnetic fields in a scanning transmission electron microscope. Different detector geometries can be used for imaging and, due to their efficiency, mainly ring quadrant detectors and pixelated detectors have been used in recent high resolution differential phase contrast experiments. In 4D-Scanning Transmission Electron Microscopy one uses a pixelated (2D) detector to obtain the complete scattering distribution for every (2D) image point. The accuracy of pixelated detectors increases with an increasing number of pixels, which in turn also leads to a larger amount of data that needs to be evaluated. To reduce the required numerical effort, we are looking for alternative detector geometries by further segmenting ring quadrant detectors. To compare the different geometries, their signal-to-noise ratios are calculated for an ideal STEM and several weak phase objects. Images can be obtained by combining the data of different detector pixels using a scheme similar to a reconstruction from a focal series. The procedure can be interpreted as the simplest example of ptychography including only the first-order diffraction disks. Our results show that a 50-segment annular bright-field detector can reach a signal-to-noise ratio close to that of a 128 × 128 pixelated detector, while having a significantly lower number of segments that need to be evaluated.
Related Concept Videos
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Scanning Electron Microscopy
Fundamental Principles
Accelerated...
Transmission Electron Microscopy
Overview of Microscopy Techniques
Overview of Electron Microscopy