Related Experiment Video
Updated: Aug 13, 2025

Endotracheal Intubation Using a Flexible Intubation Endoscope as a Standardized Model for Safe Airway Management in Swine
Published on: August 25, 2022
First-Attempt Intubation Success Among Emergency Medicine Trainees by Laryngoscopic Device and Training Year: A
Samuel I Garcia1, Benjamin J Sandefur1, Ronna L Campbell1
1Department of Emergency Medicine, Mayo Clinic College of Medicine and Science, Rochester, MN.
Study Objective:
We compare intubation first-attempt success with the direct laryngoscope, hyperangulated video laryngoscope, and standard geometry video laryngoscope among emergency medicine residents at various postgraduate years (PGY) of training.
Methods:
We analyzed prospective data from emergency department (ED) patients enrolled in the National Emergency Airway Registry from January 1, 2016 to December 31, 2018 using mixed-effects logistic regression to assess the association between PGY of training and first-attempt success by the device.
Results:
Among 15,204 intubations performed by emergency medicine trainees, first-attempt success for PGY-1, PGY-2, and PGY3+ residents, respectively were: 78.8% (95% CI, 75.0 to 82.2%), 81.3% (79.4 to 83.0), and 83.6% (95% CI, 82.1 to 85.1) for direct laryngoscope; 87.2% (95% CI, 84.2 to 89.7), 90.4% (95% CI, 88.8 to 91.9%), and 91.2% (95% CI, 89.8 to 92.5%) for hyperangulated video laryngoscope; and 88.7% (95% CI, 86.1 to 90.9), 90.2% (95% CI, 88.7 to 91.5%), and 94.6% (95% CI 93.9 to 95.3%) for standard geometry video laryngoscope. Direct laryngoscope first-attempt success improved for PGY-2 (adjusted odds ratio [aOR],1.41; 95% CI, 1.09 to 1.82) and PGY-3+ (aOR, 1.76; 1.36 to 2.27) trainees compared to PGY-1. Hyperangulated video laryngoscope success also improved for PGY-2 (aOR, 1.51; 1.1 to 2.05) and PGY-3+ (aOR, 1.56; 1.15 to 2.13) trainees compared to PGY-1. For the standard geometry video laryngoscope, only PGY-3+ (aOR, 1.72; 1.25 to 2.36) was associated with improved first-attempt success compared to PGY-1.
Conclusion:
Each laryngoscopy device class was associated with improvement in first-attempt success as training progressed. The video laryngoscope outperformed the direct laryngoscope for all operator groups, and PGY-1 trainees achieved higher first-attempt success using a standard geometry video laryngoscope than PGY-3+ trainees using a direct laryngoscope. These findings support the conjecture that in adult patients, a direct laryngoscope should not be routinely used for the first intubation attempt unless clinical circumstances, such as the presence of a soiled airway, would favor its success. These findings need to be validated with prospective randomized clinical trials.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....