Evaluation of Fluid Overload by Bioelectrical Impedance Vectorial Analysis
Published on: August 17, 2022
Association between Remote Dielectric Sensing and Estimated Plasma Volume to Assess Body Fluid Distribution
Teruhiko Imamura1, Toshihide Izumida1, Nikhil Narang2
1Second Department of Internal Medicine, University of Toyama, Toyama 930-0194, Japan.
Abstract:
Background: Pulmonary congestion is quantified by a remote dielectric sensing (ReDSTM) system, while systemic congestion is estimated by calculated plasma volume. The type of clinical patient profile as defined by the ReDS system and calculated plasma volume remains uncertain. Methods: Hospitalized patients with or without heart failure were included in this prospective study. On admission, ReDS values were measured and plasma volume status (PVS) was estimated using their body weight at the same time. Cutoffs of ReDS value and PVS were defined at 34% and −2.7%, respectively. The association between the two parameters was assessed. Results: A total of 482 patients (median 76 years, 288 men) were included. The median ReDS value was 28% (25%, 32%) and median PVS was −16.4% (−26.3%, −5.9%). Of the patients, 64 had high ReDS value (and low PVS) and 80 had high PVS (and low ReDS value). The high ReDS group had a higher prevalence of clinical heart failure with a more elevated echocardiographic E/e’ ratio, whereas the high PVS group had a higher prevalence of chronic kidney disease (p < 0.05 for all). Four out of a total of six patients with high ReDS value and high PVS had both heart failure and chronic kidney disease profiles. Conclusion: The combination of ReDS value and PVS was able to clinically stratify the types of body fluid distribution and patient profiles. Utilizing these tools may assist the clinician in constructing a therapeutic strategy for the at-risk hospitalized patient.
More Related Videos
08:50Total Internal Reflection Absorption Spectroscopy TIRAS for the Detection of Solvated Electrons at a Plasma-liquid Interface
Published on: January 24, 2018
05:30Author Spotlight: Advancing the Analysis of Plasma Extracellular Vesicle Proteome for Cardiovascular Biomarker Studies
Published on: January 31, 2025
Related Concept Videos
Volume of Distribution
Drug Distribution: Volume of Distribution
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...