Coaxial-Robotic Single-Site Myomectomy: Surgical Outcomes Compared with Robotic Single-Site Myomectomy by Propensity
Su Hyeon Choi1, Seyeon Won1, Nara Lee1
1Department of Obstetrics and Gynecology, CHA Gangnam Medical Center, CHA University School of Medicine, Seoul 06135, Republic of Korea.
Background:
The aim of this study was to introduce a coaxial-robotic single-site myomectomy (C-RSSM) technique to compensate for the shortcomings of robotic single-site myomectomy (RSSM) using semi-rigid instruments and to compare the surgical outcomes of C-RSSM and RSSM.
Methods:
The medical records of 13 consecutive women who had undergone C-RSSM and 131 consecutive women who had undergone RSSM were retrospectively reviewed. Patient characteristics and surgical outcomes after propensity score matching were evaluated and compared between the two groups.
Results:
According to the propensity score matching results, the C-RSSM group had a lower estimated blood loss (75.0 vs. 210.5 mL, p = 0.001) and a shorter operating time (101.0 vs. 146.1 min, p = 0.008) relative to the RSSM group. In RSSM, there was one case of conversion to conventional laparoscopy and four cases of conversion to the multi-site robotic approach. There was no case of conversion from C-RSSM to conventional laparoscopy or the multi-site robotic approach.
Conclusions:
C-RSSM was found to be associated with shorter operative time and lower estimated blood loss. However, further prospective studies are needed to confirm these advantages.
More Related Videos
09:46Author Spotlight: Cutting-Edge Robotic Heller Myotomy Protocol for Treatment of Achalasia
Published on: February 16, 2024
05:46Introduction of Intracapsular Rotary-cut Procedures IRCP: A Modified Hysteromyomectomy Procedures Facilitating Fertility Preservation
Published on: January 17, 2019
Related Concept Videos
Comparing the Survival Analysis of Two or More Groups
Wilcoxon Signed-Ranks Test for Matched Pairs