Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Higher-order multiple primary cancers and persistent cross-site risk across human papillomavirus-related anatomical sites in the United States: a population-based Surveillance, Epidemiology, and End Results study.

Preventive medicine reports·2026
Same author

AMI-SSS01 portable phonocardiographic examination with AI-assisted assessment for detecting heart failure exacerbations in home-based medical care in Japanese primary care clinics: a study protocol for a randomised controlled feasibility trial.

BMJ open·2026
Same author

Testing and evaluating updated variants of the rurality index for Japan: a nationwide methodological study.

BMJ open·2026
Same author

Comparing conventional and generative AI-assisted task performance in physiology education.

Advances in physiology education·2026
Same author

A Decentralized, Academically Integrated Training Model for Rural General Practice in Japan: A Descriptive Program Evaluation.

Journal of general internal medicine·2026
Same author

A Responsive and Precise Particle Position Control System Combining a Sidewall-Driven Peristaltic Micropump and a High-Speed Camera.

Micromachines·2026

Related Experiment Video

Updated: Aug 13, 2025

High Speed Droplet-based Delivery System for Passive Pumping in Microfluidic Devices
10:22

High Speed Droplet-based Delivery System for Passive Pumping in Microfluidic Devices

Published on: September 2, 2009

13.9K

Pulsation Reduction Using Dual Sidewall-Driven Micropumps.

Takuto Atsumi1, Toshio Takayama1, Makoto Kaneko2

  • 1Department of Mechanical Engineering, Tokyo Institute of Technology, 2-12-1 Ookayama, Meguro-ku, Tokyo 152-8552, Japan.

Micromachines
|January 21, 2023
PubMed
Summary
This summary is machine-generated.

This study introduces a novel sidewall-driven micropump for microfluidic devices, offering a simplified, single-layer structure. Dual-pump configurations effectively reduce flow pulsation, enabling precise cell manipulation for easier, long-term experiments.

Keywords:
microfluidic devicemicropumpperistalticpulsationsidewall-driven

More Related Videos

A Cost-effective and Reliable Method to Predict Mechanical Stress in Single-use and Standard Pumps
07:34

A Cost-effective and Reliable Method to Predict Mechanical Stress in Single-use and Standard Pumps

Published on: August 5, 2015

9.5K
Microparticle Manipulation by Standing Surface Acoustic Waves with Dual-frequency Excitations
06:51

Microparticle Manipulation by Standing Surface Acoustic Waves with Dual-frequency Excitations

Published on: August 21, 2018

7.1K

Related Experiment Videos

Last Updated: Aug 13, 2025

High Speed Droplet-based Delivery System for Passive Pumping in Microfluidic Devices
10:22

High Speed Droplet-based Delivery System for Passive Pumping in Microfluidic Devices

Published on: September 2, 2009

13.9K
A Cost-effective and Reliable Method to Predict Mechanical Stress in Single-use and Standard Pumps
07:34

A Cost-effective and Reliable Method to Predict Mechanical Stress in Single-use and Standard Pumps

Published on: August 5, 2015

9.5K
Microparticle Manipulation by Standing Surface Acoustic Waves with Dual-frequency Excitations
06:51

Microparticle Manipulation by Standing Surface Acoustic Waves with Dual-frequency Excitations

Published on: August 21, 2018

7.1K

Area of Science:

  • Biotechnology
  • Microfluidics
  • Engineering

Background:

  • Current microfluidic cell manipulation methods using syringe pumps and piezoelectric actuators are unsuitable for long-term experiments.
  • Existing integrated microfluidic pumps often have complex structures, hindering mass production.

Purpose of the Study:

  • To develop a simplified, integrated micropump for microfluidic devices.
  • To reduce flow pulsation in microfluidic systems for improved cell manipulation.
  • To enable cost-effective and user-friendly cell manipulation experiments.

Main Methods:

  • Designed and fabricated a sidewall-driven micropump integrated into a microfluidic chip.
  • Utilized air pressure to deform chamber walls, creating peristaltic motion for fluid flow.
  • Implemented a dual-pump system with phased activation to minimize flow pulsation.

Main Results:

  • The single-layer sidewall-driven micropump demonstrated a simplified structure.
  • The dual-pump configuration significantly reduced flow pulsation compared to a single pump.
  • The device facilitates precise particle control within microfluidic channels.

Conclusions:

  • The proposed sidewall-driven micropump offers a viable solution for long-term, precise cell manipulation in microfluidics.
  • This technology simplifies microfluidic device fabrication and operation.
  • The dually driven system enhances flow stability, contributing to easier and more affordable cell manipulation experiments.