Related Experiment Video
Updated: Aug 13, 2025

In vitro Cannabis Exposures of Lung Epithelial Cells at the Air-Liquid Interface
Published on: June 20, 2025
In Silico Quantification of Intersubject Variability on Aerosol Deposition in the Oral Airway
Azadeh A T Borojeni1, Wanjun Gu1, Bahman Asgharian2
1Department of Medicine, University of California, San Diego, CA 92093-0623, USA.
Abstract:
The extrathoracic oral airway is not only a major mechanical barrier for pharmaceutical aerosols to reach the lung but also a major source of variability in lung deposition. Using computational fluid dynamics, deposition of 1−30 µm particles was predicted in 11 CT-based models of the oral airways of adults. Simulations were performed for mouth breathing during both inspiration and expiration at two steady-state flow rates representative of resting/nebulizer use (18 L/min) and of dry powder inhaler (DPI) use (45 L/min). Consistent with previous in vitro studies, there was a large intersubject variability in oral deposition. For an optimal size distribution of 1−5 µm for pharmaceutical aerosols, our data suggest that >75% of the inhaled aerosol is delivered to the intrathoracic lungs in most subjects when using a nebulizer but only in about half the subjects when using a DPI. There was no significant difference in oral deposition efficiency between inspiration and expiration, unlike subregional deposition, which shows significantly different patterns between the two breathing phases. These results highlight the need for incorporating a morphological variation of the upper airway in predictive models of aerosol deposition for accurate predictions of particle dosimetry in the intrathoracic region of the lung.