Related Experiment Video
Updated: Aug 13, 2025

Quantitative Structure-Activity Relationship, Activity Prediction, and Molecular Dynamics of Non-nucleotide Reverse Transcriptase Inhibitors
Published on: May 9, 2025
Potentiometric determination of mebeverine hydrochloride antispasmodic drug based on molecular docking with different
Ahmed M Abdel-Raoof1, Manal M Fouad2,3, Noha S Rashed2
1Analytical Chemistry Department, Faculty of Pharmacy (Boys), Al-Azhar University Cairo 11751 Egypt ahmedmeetyazeed79@yahoo.com Ashraf.abdelfattah@hotmail.com.
Abstract:
The scientific community has continued to pay particular attention to potentiometric sensors based on ion-selective membrane sensors as an energy-efficient, easy-to-use method suitable for microfabrication. To this end, potentiometric ion-selective sensors were used as an alternative green analytical instrument. Three distinct sensors relying on various ionophores were built and assessed. A cationic exchanger, tetra phenyl borate, was used in the polyvinyl chloride polymeric plasticized matrix using di octyl phthalate, where α, β, and γ cyclodextrins were utilized as ionophores. A comparative potentiometric analysis was carried out using three ion-selective sensor designs: α, β, and γ cyclodextrins sensors. β-Cyclodextrin significantly reduced the detection limit and improved the discriminative performance of mebeverine hydrochloride (MBV) in the pharmaceutical dosage form over α- and γ-cyclodextrins in the presence of other interfering chemicals. Additionally, a significant connection was made between the practical perspective and a theoretical investigation based on computational research. Nernstian potentiometric results for the optimum sensor were obtained for MBV in the range of concentrations 1.0 × 10-2 to 1.0 × 10-6 M, its slope was -58.70 ± 0.12 mV per decade with lower detection limits 4.50 × 10-7 M. This computational molecular docking investigation clarified that the binding sites and modes were in good agreement with the experiment results. This investigation was applied to expect the interaction between MBV and the proposed sensors to ensure which ionophores were the best for MBV.
More Related Videos
05:08Application of I TASSER, trRosetta, UCSF Chimera, HADDOCK server, and HEX loria for De Novo and In Silico Design of Proteins
Published on: July 8, 2025
08:49Incorporating Target Protein Structure Flexibility and Dynamics in Computational Drug Discovery Using Ensemble-Based Docking Analysis
Published on: June 20, 2025
Related Concept Videos
Protein-Drug Binding: Determination Methods
Indirect methods involve isolating the bound drug from its free form in biological samples such as blood, serum, or plasma. These techniques aim to measure the percentage of drugs bound to proteins. Equilibrium dialysis is a commonly used method where the free drug concentration at equilibrium is measured by separating the bound...
The Equilibrium Binding Constant and Binding Strength
Molecular Geometry and Dipole Moments