Evaluation of silicone rubber-lead shield's effectiveness in protecting the breast during thoracic CT
Yulianti M Lestari1, Choirul Anam1, Heri Sutanto1,2
1Department of Physics, Diponegoro University, Semarang, Indonesia.
Abstract:
Radiation of thoracic computed tomography (CT) involves the breast although it is not considered an organ of interest. According to the International Commission on Radiological Protection (ICRP) No. 103, the breast is an organ with a high level of sensitivity when interacting with x-rays, increasing the potential risk of breast cancer. Therefore, the radiation dose must be optimized while maintaining image quality. The dose optimization can be accomplished using a radiation shield. This study aims to determine the effect of silicone rubber (SR)-lead (Pb) in various thicknesses as an alternative protective material limiting dose and preserving the image quality of the breast in thoracic CT. SR-Pb was made from SR and Pb by a simple method. The SR-Pb had thicknesses of 3, 6, 9, and 12 mm. The breast dose was measured using a CT dose profiler on the surface of the breast phantom. The CT number and the noise level of the resulting image were determined quantitatively. The dose without the radiation shield was 5.4 mGy. The doses measured using shielding with thicknesses of 3, 6, 9, and 12 mm were 5.2, 4.5, 4.3, and 3.3 mGy, respectively. Radiation shielding with a thickness of 12 mm reduced breast surface dose by up to 38%. The CT numbers and noise levels for the left and right breast phantom images were almost the same as those without radiation shields indicating there were only slight artifacts in the image. Therefore, SR-Pb is considered a good shielding material which can be pplied in a clinical setting by placing it directly on the breast surface for dose optimization.
More Related Videos
12:57X-Ray Visualization of Intraductal Ethanol-Based Ablative Treatment for Prevention of Breast Cancer in Rat Models
Published on: December 9, 2022
05:26Two-Dimensional X-Ray Angiography to Examine Fine Vascular Structure Using a Silicone Rubber Injection Compound
Published on: January 7, 2019
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System V: CT