Related Experiment Video
Updated: Aug 13, 2025

Fully Endoscopic Mitral Valve Repair with Percutaneous Cannulation of Groin Vessels
Published on: May 26, 2023
Routine use of percutaneous femoral cannulation in minimally invasive cardiac surgery
Kristina Ma1, Mikael Kastengren2,3, Peter Svenarud1,3
1Department of Cardiothoracic Surgery, Karolinska University Hospital, Stockholm, Sweden.
Objectives:
Large series of percutaneous femoral access for extracorporeal circulation in minimally invasive cardiac surgery (MICS) are scarcely reported.
Methods:
This is a single-centre study describing the use of percutaneous femoral access in patients undergoing MICS via minithoracotomy. Femoral artery closure was performed with a plug-based closure device. To reduce the risk for vascular complications, intraoperative ultrasound assessment of correct deployment of the arterial closure device was done during the later period of the study.
Results:
During a 5-year period, 650 patients underwent percutaneous femoral cannulation and decannulation with device closure of the femoral artery puncture. Two hundred and seven patients (31.8%) were operated in the early phase of the experience (August 2017-August 2019), without the use of intraoperative ultrasound assessment of closure device deployment. During the later period of our experience (August 2019-September 2022), 443 patients (68.2%) were operated, of whom all underwent intraoperative ultrasound assessment of closure device deployment. Of the patients operated without intraoperative ultrasound assessment, 6 patients (2.9%) experienced vascular complications compared with none of the patients in whom intraoperative ultrasound-assessment was used (P < 0.001). In total, 15 patients (2.3%) underwent conversion to surgical cutdown owing to incomplete haemostasis or femoral artery stenosis/occlusion and the mechanism was intravascular deployment of the closure device in all 15 cases.
Conclusions:
Percutaneous femoral access in MICS is safe and the need for surgical cutdown was infrequent. The risk for vascular complications is minimized with the use of intraoperative ultrasound assessment of the correct positioning of the vascular closure device.
Clinical Trial Registration Number:
http://www.clinicaltrials.gov; Unique identifier: NCT05462769.
Insights
Percutaneous femoral access for minimally invasive cardiac surgery (MICS) is safe. Intraoperative ultrasound assessment of vascular closure devices significantly reduces vascular complications, making surgical cutdown infrequent.
Area of Science:
- Cardiovascular Surgery
- Minimally Invasive Surgery
- Vascular Access
Background:
- Percutaneous femoral access is increasingly used for extracorporeal circulation in minimally invasive cardiac surgery (MICS).
- Large-scale reports on percutaneous femoral access for MICS are limited.
- Ensuring safe and effective vascular closure is critical for this approach.
Purpose of the Study:
- To evaluate the safety and efficacy of percutaneous femoral access for MICS.
- To assess the impact of intraoperative ultrasound guidance on vascular complication rates.
- To determine the frequency of conversion to surgical cutdown.
Main Methods:
- A single-center study of 650 patients undergoing MICS via minithoracotomy with percutaneous femoral cannulation.
- Femoral artery closure was performed using a plug-based device.
- Intraoperative ultrasound assessment of closure device deployment was implemented in the later phase of the study.
Main Results:
- Vascular complications occurred in 2.9% of patients without intraoperative ultrasound assessment versus 0% with ultrasound assessment (P < 0.001).
- A total of 2.3% of patients required conversion to surgical cutdown due to issues like incomplete hemostasis or femoral artery stenosis/occlusion.
- Intravascular deployment of the closure device was the mechanism for all conversions to surgical cutdown.
Conclusions:
- Percutaneous femoral access is a safe method for MICS.
- The use of intraoperative ultrasound assessment for vascular closure devices minimizes the risk of vascular complications.
- Surgical cutdown for femoral artery access in MICS is infrequent when proper closure techniques are employed.
More Related Videos
13:26Basic Surgical Techniques in the Göttingen Minipig: Intubation, Bladder Catheterization, Femoral Vessel Catheterization, and Transcardial Perfusion
Published on: June 26, 2011
07:39Use of a Percutaneous Ventricular Assist Device/Left Atrium to Femoral Artery Bypass System for Cardiogenic Shock
Published on: August 16, 2021
Related Concept Videos
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Catheterization IV: Nursing Management
Cardiac Catheterization II: Right Heart Catheterization