Related Experiment Video
Updated: Aug 12, 2025

Leveraging Turbidity and Thromboelastography for Complementary Clot Characterization
Published on: June 4, 2020
Blood component requirements in liver transplantation: effect of 2 thromboelastometry-guided strategies for bolus
Marta Caballero1, Antoni Sabate1, Rosa Gutierrez2
1Department of Anesthesiology, University Hospital of Bellvitge. University of Barcelona Health Campus, IDIBELL, Barcelona, Spain.
Background:
A low plasma fibrinogen level influences blood component transfusion. Thromboelastometry provides clinical guidance for fibrinogen replacement in liver transplantation (LT).
Objectives:
We hypothesized that infusions of fibrinogen concentrate to reach an A10FibTem value of 11 mm during LT could reduce red blood cell (RBC) and other component and fluid requirements in comparison to standard care.
Methods:
This randomized, blinded, multicenter trial in 3 hospitals enrolled 189 LT-scheduled patients allocated to an intervention target (A10FibTem, 11 mm) or a standard target (A10FibTem, 8 mm); 176 patients underwent LT with fibrinogen replacement. Data were analyzed by intention-to-treat (intervention group, 91; control group, 85). Blood was extracted, and fibrinogen kits were prepared to bring each patient's fibrinogen level to the assigned target at the start of LT, after portal vein clamping, and after graft reperfusion. The main outcome was the proportion of patients requiring RBC transfusion during LT or within 24 hours.
Results:
The proportion of patients requiring RBCs did not differ between the groups: intervention, 74.7% (95% CI, 65.5%-83.3%); control, 72.9% (95% CI, 62.2%-82.0%); absolute difference, 1.8% (95% CI, -11.1% to 14.78%) (P = .922). Thrombotic events occurred in 4% of the patients in both groups; reoperation and retransplantation rates and mortality did not differ. Nearly 70% of the patients in both groups required fibrinogen concentrate to reach the target. Using an 11-mm A10FibTem target increased the maximum clot firmness without affecting safety. However, this change provided no clinical benefits.
Conclusion:
The similar low plasma fibrinogen concentrations could explain the lack of significant between-group outcomes.
Related Concept Videos
Blood Transfusion and Agglutination
History
The history of blood transfusion dates back to the 17th century, when early attempts were made in animals. In 1818 James Blundell, a British doctor, performed the first successful human blood transfusion. Later in 1900, Karl...
Blood Transfusion
Blood Transfusion Overview
A blood transfusion is a medical procedure used to replace blood lost due to injury, surgery, or to treat conditions such as anemia or cancer. During a transfusion, donor blood is...
Venous Thrombosis III: Interprofessional Care