Related Experiment Video
Updated: Aug 12, 2025

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Complications After Volar Locking Plate Fixation of Distal Radius Fractures: A Retrospective Study of 822 Patients
Søren Perregaard1, Rasmus Wejnold Jørgensen1, Marcus Landgren2
1Department of Orthopedic Surgery, Hand Surgery Unit, Copenhagen University Hospital, Herlev and Gentofte, Gentofte, Denmark.
Purpose:
With the current routine use of volar locking plates as the preferred surgical treatment option for distal radius fractures, the purpose of this study was to investigate the incidence of postoperative complications following surgery and, second, investigate the correlation between demographic factors and the risk of complications.
Methods:
We retrospectively reviewed all patients who had been surgically treated for a distal radius fracture with open reduction and internal fixation using volar plating and screws during a 3-year period. Relevant demographic information and all postoperative complications of the 822 patients eligible for inclusion were recorded, with a mean follow-up time of 2.8 years.
Results:
We identified an overall complication rate of 12.3% (101 of the 822 patients), with 4.8% defined as experiencing major complications and 7.5% defined as experiencing minor complications. The most frequent were complications that led to hardware removal, observed in 2.7% (n = 22) of the patients; wound-related problems that did not require surgical revision, observed in 2.2% (n = 18) of the patients; and carpal tunnel syndrome, observed in 1.9% (n = 16) of the patients. Binary logistic regression modeling showed no correlation between demographic factors and the risk of complications.
Conclusions:
In conclusion, a low overall complication rate of 12.3% was found. Further, 4.8% of the patients experienced a major complication and 7.5% of the patients experienced a minor complication following open reduction and internal fixation using volar plating of distal radius fractures. Age, sex, fracture type, and time from trauma to surgery were not found to be associated with an increased risk of postoperative complications.
Type Of Study/Level Of Evidence:
Prognostic IV.
More Related Videos
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a...