Related Experiment Video
Updated: Aug 12, 2025

A Novel Inhalation Mask System to Deliver High Concentrations of Nitric Oxide Gas in Spontaneously Breathing Subjects
Published on: May 4, 2021
The Relationship of Respiratory Rate-Oxygenation (ROX) and Modified ROX Index With High-Flow Nasal Cannula Oxygen
Habib Md R Karim1, Abhishek Bharadwaj1, Omer M Mujahid2
1Anesthesiology, Critical Care, and Pain Medicine, All India Institute of Medical Sciences, Raipur, IND.
Abstract:
Background and aim Respiratory Rate-Oxygenation (ROX) and modified ROX (mROX) indexes have been proposed to detect early high-flow nasal cannula (HFNC) therapy failure. We evaluated the utility and relationship of ROX and mROX indexes in COVID-19 patients started on HFNC oxygen therapy. Methods This pilot study collected data from adult COVID-19 patients requiring HFNC oxygenation from 29 Jan - 29 Jun 2021. The patients were divided into two cohorts based on HFNC therapy success. ROX and mROX were compared using statistical diagnostic testing, including receiver operating characteristics and area under the curve (AUC) using online Epitools (https://epitools.ausvet.com.au/) and MedCalc software (MedCalc Software Ltd, Ostend, Belgium, https://www.medcalc.org/); p<0.05 was considered significant. Results Twenty-seven patients fulfilled the inclusion criteria; 48.15% of therapy failed. The cohort's mean ± standard deviation age was 53.93 ± 10.67 years; 74.1% were male. The accuracy of predicting failure for mean ROX versus mROX at baseline and six-hour values was 59.81 versus 70.68 and 67.42 versus 74.88, respectively (all p>0.05). The AUC for ROX and mROX at baseline and at six hours were statistically indifferent. Only an mROX of 4.05 (mean value) and 3.34 (Youden's J cut-off) had a sensitivity plus specificity at 156% and 163%, respectively. Conclusion Both ROX and mROX at baseline and six hours had fair-to-good accuracies and AUC; the differences were insignificant. Both ROX and mROX had better accuracies at six hours. However, only mROX < 4.05 at six hours fulfilled the sensitivity plus specificity criteria to be a clinically valuable screener.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
07:23Retinal Vascular Reactivity as Assessed by Optical Coherence Tomography Angiography
Published on: March 26, 2020
Related Concept Videos
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Acute Respiratory Failure-IV