Related Experiment Video
Updated: Aug 12, 2025

Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
Is tendinitis in volar plating related to the dorsally protruding screw length and its compartment?
Taner Alic1, Nurdan Fidan, Ercan Hassa
1Hitit Üniversitesi Tıp Fakültesi, Ortopedi ve Travmatoloji Anabilim Dalı, 19040 Çorum, Türkiye. taneralic@gmail.com.
Objectives:
The aim of this study was to evaluate the relationship between the length of the protruded screws from the dorsal cortex and extensor tendon damage in all compartments.
Patients And Methods:
Between May 2020 and April 2021, a total of 29 patients (13 males, 16 females; mean age: 52.3±13.0 years; range, 30 to 78 years) who were operated and followed in our clinic for AO A2 and A3 distal radius fractures were included in this prospective study. Surface ultrasound (US) imaging was made to the dorsal sides of both wrists of the operated patients at different timepoints postoperatively. The length of screws with radius dorsal cortex penetration and the presence of tendinitis were recorded.
Results:
In 15 of 23 patients, the presence of 29 protruding screws was accompanied by tendinitis and, in eight patients, no tendinitis was observed, despite the partial protrusion of screws. A statistically significant correlation was found between the screw protrusion and presence of tendinitis (p<0.05). The number of protruding screws and tendinitis were seen mostly in the second compartment. There was a statistically significant correlation between the protruding screw length of >1.6 mm and the presence tendinitis (p<0.05).
Conclusion:
Dorsal cortex screw protrusions in the application of volar plate for distal radius fractures can cause tendinitis. Screw protrusions occur more frequently in the second compartment and the development of tendinitis in this compartment is associated with a screw length of >1.6 mm. Screw penetration can be easily identified with intraoperative US to prevent tendinitis and potential tendon ruptures.
More Related Videos
06:41A Minimally Invasive Model to Analyze Endochondral Fracture Healing in Mice Under Standardized Biomechanical Conditions
Published on: March 22, 2018
06:38Establishment of a Segmental Femoral Critical-size Defect Model in Mice Stabilized by Plate Osteosynthesis
Published on: October 12, 2016
Related Concept Videos
Screw: Problem Solving
To evaluate the...
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Saint-Venant's Principle
Plastic Deformation in Circular Shafts