Related Experiment Video
Updated: Aug 12, 2025

Author Spotlight: Assessing the Reliability of Doppler Ultrasound in Measuring Leg Blood Flow
Published on: December 15, 2023
Does the osteopathic pedal pump reduce lower limb volume in healthy subjects?
Jill S Adams1, Sahil H Parikh1, Brandon J Goodwin1
1Rowan-Virtua School of Osteopathic Medicine, Stratford, NJ, USA.
Context:
Lymphatic treatments are gentle and passive techniques believed to enhance movement of lymph back into the central circulatory system. Animal studies provide supportive evidence, yet there are few studies in humans.
Objectives:
The aim of this study is to investigate whether the osteopathic pedal pump protocol reduces volume in the lower limbs of healthy subjects.
Methods:
A total of 30 first- and second-year medical students were recruited. Subjects were excluded from participating if they had acute asthma, chronic obstructive pulmonary disease (COPD), congestive heart failure, active infections, fractures of the lower extremities, or metastatic cancer. A within-subjects study design with pre- and posttreatment measurement of lower limb volume was utilized. Pretreatment lower limb volume measurements were obtained utilizing a volumetric water gauge prior to myofascial thoracic inlet release and a 5 min pedal lymphatic pump protocol treatment. Posttreatment lower limb measurements were taken immediately following the protocol treatment. A telephone interview was conducted 2-3 days after the treatment to assess the participants' experience of the treatment and whether the treatment elicited a subjective change from baseline. A paired t test was utilized to determine the statistical significance of volume displacement posttreatment.
Results:
The mean change of pretreatment to posttreatment lower limb volume was -45.63 mL with a standard deviation of 37.65 mL. The change between the pretreatment and posttreatment volume measurements was statistically significant (p<0.001). The minimum displacement was +19 mL, and the maximum displacement was -167 mL. The majority of participants perceived the treatment as effective and enjoyable, were likely to recommend it to others, and were willing to have it performed on them at routine office visits if there was a need.
Conclusions:
The osteopathic pedal pump technique, when utilized on those without leg lymphedema, reduces lower limb volume as measured by the volumetric water gauge. Further studies are warranted, especially in persons with excess lower-extremity edema, lymphedema or venous stasis.
Related Concept Videos
Pulse Assessment Sites
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
Assessing Blood pressure in the Leg
Preparation:
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...

