Effect of microchannel geometry and linker molecules on surface immobilization efficiency of proteins in microfluidic
Senjuti Chakraborty1, Siddhant Jaitpal1, Sourav Acharya1
1Department of Biosciences and Bioengineering, Indian Institute of Technology Bombay, Powai, Mumbai 400076, India.
Abstract:
One of the key metrics in the design of biosensors is the presence of an effective capture layer. Surface-immobilized proteins (especially as a part of antibody-antigen combinations) are the most commonly used capture ligands in biosensors. The surface coverage of these proteins in flow-based biosensors are affected by both the linker chemistry used to attach them as well as the microchannel geometry. We used streptavidin as a model protein to compare glutaraldehyde, EDC-NHS, sulfo-SMCC and sulfo-NHS-biotin as linkers inside straight, serpentine and square-wave microchannel geometries. We found that straight microchannels achieve the highest degree of protein immobilization compared to serpentine and square-wave microchannels, irrespective of the linker chemistry used. We also showed that for a given microchannel geometry, sulfo-NHS-biotin leads to the highest immobilization of streptavidin among all the linkers.