Raman spectroscopy and convolutional neural networks for monitoring biochemical radiation response in breast tumour xenografts
Related Experiment Video
Updated: Aug 12, 2025

Biomolecular Imaging of Cellular Uptake of Nanoparticles using Multimodal Nonlinear Optical Microscopy
Published on: May 16, 2022
Alejandra M Fuentes1, Apurva Narayan2,3, Kirsty Milligan1
1Department of Physics, The University of British Columbia Okanagan Campus, Kelowna, Canada.
Abstract:
Tumour cells exhibit altered metabolic pathways that lead to radiation resistance and disease progression. Raman spectroscopy (RS) is a label-free optical modality that can monitor post-irradiation biomolecular signatures in tumour cells and tissues. Convolutional Neural Networks (CNN) perform automated feature extraction directly from data, with classification accuracy exceeding that of traditional machine learning, in cases where data is abundant and feature extraction is challenging. We are interested in developing a CNN-based predictive model to characterize clinical tumour response to radiation therapy based on their degree of radiosensitivity or radioresistance. In this work, a CNN architecture is built for identifying post-irradiation spectral changes in Raman spectra of tumour tissue. The model was trained to classify irradiated versus non-irradiated tissue using Raman spectra of breast tumour xenografts. The CNN effectively classified the tissue spectra, with accuracies exceeding 92.1% for data collected 3 days post-irradiation, and 85.0% at day 1 post-irradiation. Furthermore, the CNN was evaluated using a leave-one-out- (mouse, section or Raman map) validation approach to investigate its generalization to new test subjects. The CNN retained good predictive accuracy (average accuracies 83.7%, 91.4%, and 92.7%, respectively) when little to no information for a specific subject was given during training. Finally, the classification performance of the CNN was compared to that of a previously developed model based on group and basis restricted non-negative matrix factorization and random forest (GBR-NMF-RF) classification. We found that CNN yielded higher classification accuracy, sensitivity, and specificity in mice assessed 3 days post-irradiation, as compared with the GBR-NMF-RF approach. Overall, the CNN can detect biochemical spectral changes in tumour tissue at an early time point following irradiation, without the need for previous manual feature extraction. This study lays the foundation for developing a predictive framework for patient radiation response monitoring.
Insights
Convolutional Neural Networks (CNNs) effectively identify radiation effects in tumour tissue using Raman spectroscopy, predicting patient response to radiation therapy with high accuracy and enabling early monitoring.
Area of Science:
- Biomedical Optics
- Computational Biology
- Cancer Research
Background:
- Tumour cells develop altered metabolism, leading to radiation resistance and disease progression.
- Raman spectroscopy (RS) is a label-free technique for analyzing biomolecular changes in tissues post-irradiation.
- Convolutional Neural Networks (CNNs) excel at automated feature extraction from complex data, outperforming traditional methods.
Purpose of the Study:
- To develop a CNN-based predictive model for characterizing clinical tumour response to radiation therapy.
- To identify radiosensitivity or radioresistance based on post-irradiation spectral changes.
- To establish a foundation for a patient radiation response monitoring framework.
Main Methods:
- A CNN architecture was designed to detect spectral changes in Raman spectra of irradiated tumour tissue.
- The model was trained using Raman spectra from breast tumour xenografts, classifying irradiated versus non-irradiated samples.
- Validation included a leave-one-out approach (mouse, section, Raman map) to assess generalization.
Main Results:
- The CNN achieved high classification accuracies: >92.1% at 3 days and 85.0% at 1 day post-irradiation.
- The model demonstrated strong generalization capabilities with average accuracies ranging from 83.7% to 92.7% in leave-one-out validation.
- CNN outperformed a GBR-NMF-RF model in accuracy, sensitivity, and specificity for mice assessed 3 days post-irradiation.
Conclusions:
- CNNs can accurately detect early biochemical spectral changes in tumour tissue after irradiation without manual feature extraction.
- This approach shows promise for predicting patient response to radiation therapy.
- The study provides a basis for developing a predictive framework for real-time radiation response monitoring.
More Related Videos
07:54Surface-enhanced Resonance Raman Scattering Nanoprobe Ratiometry for Detecting Microscopic Ovarian Cancer via Folate Receptor Targeting
Published on: March 25, 2019
07:37An Integrated Raman Spectroscopy and Mass Spectrometry Platform to Study Single-Cell Drug Uptake, Metabolism, and Effects
Published on: January 9, 2020