Related Experiment Video
Updated: Aug 12, 2025

Lung Rapid Recovery Procurement Combined with Abdominal Normothermic Regional Perfusion in Controlled Donation after Circulatory Death
Published on: August 15, 2022
Triaging donor lungs based on a microaspiration signature that predicts adverse recipient outcome
Rayoun Ramendra1, Andrew T Sage1, Jonathan Yeung2
1Toronto Lung Transplant Program, Ajmera Transplant Center, University Health Network, Toronto, Ontario, Canada; Toronto General Hospital Research Institute, University Health Network, Toronto, Ontario, Canada.
Background:
Aspiration is a relative contraindication to accepting donor lungs for transplant and is currently assessed by visual inspection of the airways via bronchoscopy. However, this method is limited as it does not assess for microaspiration. Bile acids measured in large airway bronchial wash (LABW) samples have been shown to be a marker of aspiration in lung transplant recipients. Herein, we investigate the utility of measuring total bile acids (TBA) in donor LABW to predict performance of donor lungs and recipient outcomes.
Methods:
TBA was measured in 605 consecutive lung donors at the Toronto Lung Transplant Program. TBA levels were compared in donor lungs deemed unsuitable for transplant, requiring further assessment on ex vivo lung perfusion (EVLP), and those suitable for direct transplantation using Mann-Whitney-U tests. Relationships between LABW TBA concentrations and recipient outcomes were evaluated using multivariable Cox-PH models and log-rank analysis.
Results:
Donor TBA was highest in lungs deemed unsuitable for transplant and correlated with clinical assessment of aspiration. LABW TBA concentration correlated with calcium, decreased pH, and increased pro-inflammatory mediators in EVLP perfusate. TBA cut-off of 1245 nM was able to differentiate donor lungs directly declined from those suitable for direct transplantation with a 91% specificity (AUROC: 73%). High donor TBA status was associated with the increased rate of primary graft dysfunction, longer time to extubation, and shorter time to chronic lung allograft dysfunction.
Conclusions:
In a large retrospective cohort, we observed that donor LABW TBA was associated with suitability of donor lungs for transplant, performance of the organ on EVLP, and adverse recipient outcomes.