Background:
We have demonstrated that a neural network is able to predict a person's age from the electrocardiogram (ECG) [artificial intelligence (AI) ECG age]. However, some discrepancies were observed between ECG-derived and chronological ages. We assessed whether the difference between AI ECG and chronological age (Age-Gap) represents biological ageing and predicts long-term outcomes.
Methods And Results:
We previously developed a convolutional neural network to predict chronological age from ECGs. In this study, we used the network to analyse standard digital 12-lead ECGs in a cohort of 25 144 subjects ≥30 years who had primary care outpatient visits from 1997 to 2003. Subjects with coronary artery disease, stroke, and atrial fibrillation were excluded. We tested whether Age-Gap was correlated with total and cardiovascular mortality. Of 25 144 subjects tested (54% females, 95% Caucasian) followed for 12.4 ± 5.3 years, the mean chronological age was 53.7 ± 11.6 years and ECG-derived age was 54.6 ± 11 years (R 2 = 0.79, P < 0.0001). The mean Age-Gap was small at 0.88 ± 7.4 years. Compared to those whose ECG-derived age was within 1 standard deviation (SD) of their chronological age, patients with Age-Gap ≥1 SD had higher all-cause and cardiovascular disease (CVD) mortality. Conversely, subjects whose Age-Gap was ≤1 SD had lower all-cause and CVD mortality. Results were unchanged after adjusting for CVD risk factors and other survival influencing factors.
Conclusion:
The difference between AI ECG and chronological age is an independent predictor of all-cause and cardiovascular mortality. Discrepancies between these possibly reflect disease independent biological ageing.
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Blood Studies for Cardiovascular System II: CRP, Hcy, and Cardiac Natriuretic Peptide Markers
These markers indicate stress or strain on the heart muscle:
Natriuretic Peptides (BNP)
Cardiac myocytes produce these hormones in response to ventricular stretching...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....