Related Experiment Video
Updated: Aug 12, 2025

An Inverse Analysis Approach to the Characterization of Chemical Transport in Paints
Published on: August 29, 2014
Theoretical Analysis of a Nonequilibrium Transport Model of Two-Dimensional Nonisothermal Reactive Chromatography
Sadia Perveen1, Muhammad Afraz Rasheed1, Samra Sana1
1Department of Mathematics, Air University, Islamabad, 44000, Pakistan.
Abstract:
The current study investigates a nonequilibrium and nonlinear two-dimensional lumped kinetic transport model of nonisothermal reactive liquid chromatography, considering the Bi-Langmuir adsorption isotherm, heterogeneous reaction rates, radial and axial concentration variations, and the adsorption and reaction enthalpies. The mathematical models of packed bed chromatographic processes are expressed by a highly nonlinear system of coupled partial differential algebraic equations connecting the phenomena of convection, diffusion, and reaction, for mass and energy balance, the differential algebraic equations for mass balance in the solid phase, and the algebraical expressions for the adsorption isotherms and for the reaction rates. The nonlinearity of the reaction term and the adsorption isotherm preclude the derivation of an analytical solution for the model equations. For this reason, a semidiscrete, high-resolution, finite-volume technique is extended and employed in this study to obtain the numerical solution. Several consistency checks are performed to evaluate the model predictions and analyze the precision of the proposed numerical scheme. A number of heterogeneously catalyzed stoichiometric reactions are numerically simulated to examine reactor performance under the influence of temperature and Bi-Langmuir adsorption dynamics, the level of coupling between mass and energy fronts, and to study the effects of various critical parameters. The numerical results obtained are beneficial for optimal predictive control and process optimization during production and the development of methods for systematic design and fault detection of nonisothermal liquid chromatographic reactors, and hence constitute the first step to provide deeper insight into the overall evaluation of integrated reaction and separation processes.
Related Concept Videos
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
Analyte Adsorption and Distribution
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Chromatographic Methods: Terminology
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...

