Phantom equivalent thicknesses in diagnostic radiology.

R Carrier1, N Blais

  • 1Hôpital Notre-Dame, Département de Physique Biomédicale, Montréal, Québec, Canada.

Physics in Medicine and Biology
|September 1, 1987
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Avelumab plus sacituzumab govitecan versus avelumab monotherapy as first-line maintenance treatment in patients with advanced urothelial carcinoma: JAVELIN Bladder Medley interim analysis.

Annals of oncology : official journal of the European Society for Medical Oncology·2025
Same author

A Phase II Study of Neoadjuvant Opnurasib KRAS G12C Inhibitor in Patients With Surgically Resectable Non-Small Cell Lung Cancer (CCTG IND.242A): A Substudy of the IND.242 Platform Master Protocol.

Clinical lung cancer·2024
Same author

Immune checkpoint blockers in solid organ transplant recipients and cancer: the INNOVATED cohort.

ESMO open·2024
Same author

Trematodes coupled with neonicotinoids: effects on blood cell profiles of a model amphibian.

Parasitology research·2021
Same author

Clarifying the absence of evidence regarding human health risks to microplastic particles in drinking-water: High quality robust data wanted.

Environment international·2020
Same author

Consensus statement: summary of the Quebec Lung Cancer Network recommendations for prioritizing patients with thoracic cancers in the context of the COVID-19 pandemic.

Current oncology (Toronto, Ont.)·2020

Diagnostic radiology measurements use phantoms like water, plexiglass, aluminum, and copper. Equivalent thicknesses were simulated to relate phantom data to anatomical organs, considering scatter parameters.

Area of Science:

  • Medical Physics
  • Radiological Sciences
  • Biophysics

Background:

  • Diagnostic radiology measurements often require phantoms for standardization and calibration.
  • Commonly used phantom materials include water, plexiglass, aluminum, and copper.
  • Relating phantom measurements to real anatomical structures necessitates understanding equivalent thicknesses.

Purpose of the Study:

  • To determine equivalent thicknesses between various commonly used radiological phantoms.
  • To provide a basis for relating phantom measurements to the thicknesses of anatomical organs.
  • To investigate the influence of scattering parameters on phantom equivalent thicknesses.

Main Methods:

  • Simulations were performed using the Monte Carlo method.
  • Various phantom materials (water, plexiglass, aluminum, copper) were analyzed.

Related Experiment Videos

  • The impact of antiscatter grids, intensifier screens, and beam size on equivalent thicknesses was evaluated.
  • Main Results:

    • Equivalent thicknesses were calculated for different phantom materials under various conditions.
    • Significant variations in equivalent thicknesses were observed due to scattering parameters.
    • The study presents a comprehensive set of equivalent thickness values.

    Conclusions:

    • Equivalent phantom thicknesses are crucial for accurate translation of measurements to anatomical tissues.
    • Scattering conditions, including grid use and beam characteristics, substantially alter these equivalencies.
    • The Monte Carlo simulations provide valuable data for optimizing phantom usage in diagnostic radiology.