Related Experiment Video
Updated: Aug 12, 2025

Measuring the Influence of Magnetic Vestibular Stimulation on Nystagmus, Self-Motion Perception, and Cognitive Performance in a 7T MRT
Published on: March 3, 2023
Reference values of four measures of craniocervical stability using upright dynamic magnetic resonance imaging
Leslie L Nicholson1, Prashanth J Rao2,3, Matthew Lee4
1School of Medical Sciences, The University of Sydney, Camperdown, NSW, Australia. leslie.nicholson@sydney.edu.au.
Purpose:
To establish reference ranges for four most commonly used diagnostic measures of craniocervical instability (CCI) in three cervical sagittal positions. This necessitated development of a reliable measurement protocol using upright, dynamic MRI (udMRI), to determine differences in the extent of motion between positions, and whether age and sex correlate with these measures.
Materials And Methods:
Deidentified udMRIs of 50 adults, referred for reasons other than CCI, were captured at three positions (maximal flexion, maximal extension and neutral). Images were analyzed, providing measures of basion-axial interval, basion-axial angle, basion-dens interval (BDI) and the Grabb-Oakes line (GOL) for all three positions (12 measures per participant). All measures were independently recorded by a radiologist and neurosurgeon to determine their reliability. Descriptive statistics, correlations, paired and independent t-tests were used. Mean (± 2 SD) identified the reference range for all four measures at each craniocervical position.
Results:
The revised measurement protocol produced inter-rater reliability indices of 0.69-0.97 (moderate-excellent). Fifty adults' (50% male; mean age 41.2 years (± 9.7)) reference ranges for all twelve measures were reported. Except for the BDI and GOL when moving between neutral and full flexion, significant extents of movement were identified between the three craniocervical positions for all four measures (p ≤ 0.005). Only a minor effect of age was found.
Conclusions:
This is the first study to provide a rigorous standardized protocol for four diagnostic measures of CCI. Reference ranges are established at mid and ends of sagittal cervical range corresponding to where exacerbations of signs and symptoms are commonly reported.