Objectives:
The sympathetic skin response (SSR) is a well-established test, whereas the electrochemical skin conductance (ESC) is still under evaluation. Our aim was therefore to assess the diagnostic accuracy of ESC to detect abnormal sudomotor function, using SSR as a reference test.
Methods:
A cross sectional observational study was performed of 61 neurological patients assessed for possible sudomotor dysfunction and 50 age-matched healthy controls (HC). Patients with diagnoses of vasovagal syncope (VVS, n=25), Parkinson's disease (PD, n=15), multiple system atrophy (MSA, n=11) and peripheral neuropathies (PN, n=10) were included. Sudomotor function was assessed with SSR and ESC tests in all participants. The absence of SSR in the palms or soles indicates abnormal sudomotor function. Receiver operating characteristic (ROC) analysis was used to assess the diagnostic value of the ESC. Cardiovascular autonomic (CV-Aut) function was evaluated through the Ewing score, based on the following tests: Heart rate change with deep breathing, Valsalva ratio, 30:15 ratio, blood pressure changes on standing and during isometric exercise. A Ewing score ≥ 2 indicates the presence of CV-Aut dysfunction.
Results:
Mean SSR amplitudes and ESC values showed differences between HC and patients with MSA or PN (p < 0.05), but not in patients with VVS or PD. Absence of SSR was associated with abnormal ESC (p < 0.05). Patients with abnormal CV-Aut dysfunction had lower ESC (p< 0.05). Palm ESC (P-ESC) and sole ESC (S-ESC) assessment had a sensitivity of 0.91 and 0.95 to predict sudomotor dysfunction, with a specificity of 0.78 and 0.85, respectively. The area under ROC curve was 0.905 and 0.98, respectively.
Conclusions:
ESC in palms and soles has a high diagnostic accuracy for sudomotor dysfunction as detected by absent SSR in patients with MSA and PN.
More Related Videos
07:32Use of Galvanic Skin Responses, Salivary Biomarkers, and Self-reports to Assess Undergraduate Student Performance During a Laboratory Exam Activity
Published on: February 10, 2016
04:27Using Facial Electromyography to Assess Facial Muscle Reactions to Experienced and Observed Affective Touch in Humans
Published on: March 15, 2019
Related Concept Videos
Sensory Functions of the Skin
There are two main categories of receptors on the skin: capsulated and non-capsulated. The non-capsulated ones are mainly the pain receptors. The capsulated ones can be further categorized based on the...
Somatosensation