Interactive multi-model fault diagnosis method of switched reluctance motor based on low delay anti-interference
Yongqin Zhou1, Chongchong Wang1, Yongchao Wang1
1School of Electrical and Electronic Engineering, Harbin University of Science and Technology, Harbin, China.
Abstract:
Given fault false alarm and fault control failure caused by the decrease of fault identification accuracy and fault delay of Switched Reluctance Motor (SRM) power converter in complex working conditions, a method based on the Interactive Multi-Model (IMM) algorithm was proposed in this paper. Besides, the corresponding equivalent circuit models were established according to the different working states of the SRM power converter. The Kalman filter was employed to estimate the state of the model, and the fault detection and location were realized depending on the residual signal. Additionally, a transition probability correction function of the IMM was constructed using the difference of the n-th order to suppress the influence of external disturbance on the fault diagnosis accuracy. Concurrently, a model jump threshold was introduced to reduce delay when the matched model was switched, so as to realize the rapid separation of faults and effective fault control. The simulation and experiment results demonstrate that the IMM algorithm based on low delay anti-interference can effectively reduce the influence of complex working conditions, improve the anti-interference ability of SRM power converter fault diagnosis, and identify fault information accurately and quickly.
More Related Videos
11:53The Modular Design and Production of an Intelligent Robot Based on a Closed-Loop Control Strategy
Published on: October 14, 2017
11:44Real-Time DC-dynamic Biasing Method for Switching Time Improvement in Severely Underdamped Fringing-field Electrostatic MEMS Actuators
Published on: August 15, 2014
Related Concept Videos
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Series R—L Circuit Transients
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
Power System Three-Phase Short Circuits
Multimachine Stability
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...
Bus Impedance Matrix
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...