Related Experiment Video
Updated: Aug 12, 2025

Robotic D3 Partial Duodenal Resection with Primary Side-to-Side Anastomosis
Published on: December 15, 2023
Cold snare EMR for the removal of large duodenal adenomas
Hunter Wang1, Mayenaaz Sidhu2, Sunil Gupta2
1Department of Gastroenterology and Hepatology, Westmead Hospital, Sydney, New South Wales, Australia; Westmead Clinical School, The University of Sydney, Sydney, New South Wales, Australia; Department of Gastroenterology and Hepatology, Sydney Adventist Hospital, Sydney, New South Wales, Australia.
Background And Aims:
Large (≥15 mm) duodenal adenomas (DAs) are premalignant and require removal. Existing endoscopic resection techniques are compromised by serious adverse events (SAEs), most notably postprocedural bleeding (PPB) and perforation. To ameliorate these problems, we sought to evaluate the novel technique of cold snare EMR (CS-EMR) against the emerging standard of conventional EMR with thermal ablation of the postresection margin (EMR-T) for the safe and effective removal of DAs.
Methods:
Consecutive patients were enrolled in a single tertiary center for CS-EMR and prospectively analyzed against a previously reported cohort of EMR-T from the same center. The primary outcome was rate of SAEs. Secondary outcomes were residual or recurrent adenoma at first surveillance endoscopy (SE1) at 6 months and technical success per lesion.
Results:
Between October 2019 and July 2022, a total of 50 DAs ≥15 mm were removed via CS-EMR (median size, 30 mm [interquartile range (IQR), 19-40 mm]; mean ± standard deviation [SD] patient age, 70 ± 9.2 years) compared with 54 DAs via EMR-T (median size, 30 mm [IQR, 19-40 mm]; mean patient age, 68 ± 12.2 years). CS-EMR had a significantly lower rate of intraprocedural bleeding (2.0% vs 37%, P < .001) and PPB (4.0% vs 16.7%, P = .036). Two cases (4.0%) of immediate perforation occurred in CS-EMR; these were recognized immediately and closed with clips without sequelae. Total SAEs (16.0% vs 16.7%, P = 1) and technical success (100% vs 100%, P = 1) were identical. Recurrence at SE1 was significantly higher with CS-EMR (24.4% vs 2.3%, P = .002).
Conclusions:
CS-EMR reduces intraprocedural bleeding and PPB. However, it may increase the risk of immediate perforation and is associated with a significantly higher rate of recurrence at SE1. Further technical refinements are required to optimize endoscopic resection techniques for DAs. (Clinical trial registration number: NCT02306603.).
Related Concept Videos
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Endoscopic Procedures V: ERCP
Patient...
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures III: Video Capsule Endoscopy
Inflammatory Bowel Disease V: Surgical Management
Here are some common surgical interventions for IBD: