Related Experiment Video
Updated: Aug 12, 2025

Improving IV Insulin Administration in a Community Hospital
Published on: June 11, 2012
Efficacy, Safety, and Satisfaction with the Accu-Chek Insight with Diabeloop Closed-Loop System in Subjects with Type
Ana Chico1,2,3, Sol Navas de Solís4, María Lainez5
1Department of Endocrinology and Nutrition, Hospital Santa Creu i Sant Pau, Barcelona, Spain.
Abstract:
To evaluate the efficacy, safety and satisfaction of the closed-loop system Accu-Chek® Insight with Diabeloop™ (DBLG1™) in adults with type 1 diabetes (T1D) in real-world conditions. Patients with T1D using DBLG1 for at least 3 months were included. Glucometric parameters were analyzed at baseline, 1, 2, and 3 months after starting DBLG1. HbA1c was measured before and at 3 months. Technical issues and acute complications were recorded and patients completed a satisfaction questionnaire. Sixty-two patients were included (43 women; age 44.2 ± 11 years; diabetes duration 24.6 ± 12 years; 40 used flash and 22 continuous glucose monitoring (CGM); 45 were on insulin pump and 17 on multiple daily injections). A significant improvement was observed in the CGM-derived glucose metrics early in the first month: Time in range (%TIR) 70-180 mg/dL (54.86 ± 17 vs. 72.23 ± 10.11); time above range level 1 (%TAR1) 180-250 mg/dL (26.26 ± 13.3 vs. 19.48 ± 6.78), time above range level 2 (%TAR2) > 250 mg/dL (12.02 ± 13.09 vs. 6.14 ± 5.23), time below range level 1 (%TBR 1) 54-70 mg/dL (5.73 ± 11.5 vs. 1.67 ± 1.3), time below range level 2 (%TBR2) < 54 mg/dL (1.18 ± 1.97 vs.0.44 ± 0.49), %CV (38.66 ± 7.53 vs. 29.63 ± 3.74), median glucose (168.57 ± 36 mg/dL vs. 154.63 ± 17.55 mg/dL), and %GMI (7.37 ± 0.91 vs. 7.02 ± 0.42). Also, HbA1c decreased significantly (7.45% ± 1.05% vs. 6.95% ± 0.7%). No acute complications or serious adverse events occurred. Similar improvement was observed regardless of prior therapy or the glucose monitoring system used. Three patients discontinued DBLG1 and 21 experienced technical issues. Overall, patient satisfaction was high. Adjustments of the settings were modified in general in the direction of greater aggressiveness. A significant improvement in glycemic control without serious adverse events and a high degree of patient satisfaction were observed in this first real-world study evaluating the closed-loop system, Accu-Chek Insight with Diabeloop.
Related Concept Videos
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Diabetes Mellitus: Overview and Type I Subtype
Type 1 diabetes is an autoimmune disease in which the immune system mistakenly attacks and destroys the insulin-producing beta cells in the pancreas. As a result, the body is unable to produce sufficient insulin, and individuals with...
Diabetes: Management and Pharmacotherapy
Insulin remains the cornerstone of treatment for most patients with type 1 and many...
Diabetes: Symptoms, Diagnosis, and Complications
Insulin Formulations: Types and Delivery
Short-acting insulins are divided into...
Dipeptidyl Peptidase 4 Inhibitors

