[Efficacy of L-shaped Shielding in Interventional Radiology by Transradial Approach and Consideration of Methods for
Katsunori Yamashita1, Hiroyuki Ueno2, Tomonobu Haba3
1Department of Radiology, Hamamatsu University Hospital.
Abstract:
The present study investigated how effective an L-shaped shield was, depending on its position, in reducing a doctor's exposure to radiation during catheterization to access the transradial approach (TRA). The shield's effectiveness was evaluated by measuring the air kerma where the doctor stood under four conditions: with and without the shield, and with and without the shield in conjunction with conventional protection. To enable the shield to be positioned correctly in clinical practice, an illustrated instruction decal affixable to the shield's doctor-facing surface was produced, and the effectiveness of the decal was verified by means of a crossover test in which, as subjects of the study, different nurses set up the shield with and without the decal affixed to it. In the test, in which a human body phantom was used, the C-arm set at the PA angle, and the shield positioned 10 cm from the axilla of the phantom, the shield's effectiveness at 100 cm, 130 cm, and 160 cm above the floor where the doctor stood was 55%, 77%, and 47%, respectively. The effectiveness increased when the shield was positioned closer to the axilla. A significant difference in the positioning of the shield by the subjects was observed depending on whether or not the decal was affixed ( p<0.05, Wilcoxon signed-rank test), indicating that the use of the decal improved the positioning. It was concluded that, positioned correctly, the shield could effectively reduce the doctor's exposure to radiation during TRA.
More Related Videos
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
10:46Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...