Related Experiment Video
Updated: Aug 12, 2025

Sit-to-stand-and-walk from 120% Knee Height: A Novel Approach to Assess Dynamic Postural Control Independent of Lead-limb
Published on: August 30, 2016
Reduction of motion axis by sensitivity calibration of sensor in shape measurement instrument using normal vector
Takashi Miyawaki1, Mikiya Ikuchi2, Katsuyoshi Endo2
1Office of President, Nikon Corporation, 2-15-3 Kounan, Minato-ku, Japan.
Abstract:
High-precision free-form surface mirrors are required for synchrotron radiation facilities in the scientific field and semiconductor lithography systems in the industrial field. Previously, we developed a nano-profiler with the goal of achieving a measurement accuracy of 30 nm. The nano-profiler scanned and measured the slope angle of the surface to be measured with laser light and calculated the shape from the angle information. By driving the optical head and surface to be measured with four rotation axes and one translation axis, the surface could be scanned while keeping the optical path length constant. Although the rotation axis was controlled by a high-precision rotary encoder, pitching and yawing errors occurred in the translation axis. In this study, we attempt to eliminate the error of pitching and yawing from the conventional measurement operation of four axes of rotation and one axis of translation to the drive of only four axes of rotation. If the translation drive is eliminated, the optical path length will not be constant, and the sensitivity of the light-receiving element will change. Therefore, we propose a new method to calibrate the sensitivity of the receiving element and perform a comparative measurement with the conventional measurement method. Comparing the measured shapes obtained by both measurement results, it was found that the shapes had a maximum peak to valley difference of 6.2 nm. Thus, the proposed novel measurement method allows a significant reduction in pitching and yawing errors.
Related Concept Videos
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Calibration Curves: Correlation Coefficient
Distance Corrections
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Measurements of Strain