Design and development of mechanical test bench for testing and calibration of multiple blood pressure measuring
Rahul Kumar1, Afaqul Zafer1, P K Dubey1
1CSIR-National Physical Laboratory, Dr. K. S. Krishnan Marg, New Delhi 110012, India.
Abstract:
Blood pressure (BP) measurement is an important physiological parameter for human health monitoring, which plays a significant role in the diagnosis of many incurable diseases. However, due to inaccuracies in the different types of BP measuring devices, the calibration of these BP measuring instruments is a major concern for a medical practitioner. Currently, these devices' calibration, testing, and validation are performed using rigorous methods with complex clinical trials and following the available documentary standards. This article describes the design and development of an indigenous mechanical test bench (MTB) system for the testing and calibration of multiple BP devices, as per International Organization of Legal Metrology (OIML) recommended documents e.g., OIML R 16-1 and OIML R 16-2. The developed system can test and calibrate 20 BP devices, simultaneously. The traceability of the developed MTB is established by performing its calibration against the Air Piston Gauge, a national primary vacuum standard. The estimated expanded measurement uncertainty evaluated is found to be ±0.11 mmHg, which is almost one order better than the measurement uncertainty required for the test and calibration of BP measuring instruments as per standard. The MTB has successfully been used to test and calibrate several BP measuring instruments. The data of one such device is reported herein as an indicator of the performance process. The calibration of these BP measuring instruments was performed in the static mode, and the estimated expanded measurement uncertainty was found to be ±1.25 mmHg. The developed MTB system would prove to be an excellent instrument for calibration laboratories, hospitals, regulatory agencies, and other users to test and calibrate 20 BP measuring devices simultaneously and cost-effectively.
More Related Videos
09:38Determining Pain Detection and Tolerance Thresholds Using an Integrated, Multi-Modal Pain Task Battery
Published on: April 14, 2016
06:45Development of a Benchtop Model for Evaluating the Compatibility of Wound Dressing Materials with Negative Pressure Wound Therapy Systems
Published on: May 2, 2025
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Errors occurring during blood pressure monitoring
Several factors...
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: