Related Experiment Video
Updated: Aug 12, 2025

Production of Disulfide-stabilized Transmembrane Peptide Complexes for Structural Studies
Published on: March 6, 2013
[Separation of chiral compounds using high performance liquid chromatography stationary phase based on covalent
Hualin Liu1, Yanan Li1, Min Zi1
1School of Chemistry and Chemical Engineering,Yunnan Normal University,Kunming 650500,China.
Abstract:
Covalent organic frameworks (COFs) are an emerging class of porous crystalline materials composed of multidentate organic units connected by covalent bonds. COFs have been demonstrated to exhibit great potential and research value in many fields, including gas storage and separation, photoelectric devices, fluorescence sensors, catalysis, drug delivery, dye and pollutant adsorption, and electronic devices, and so on. The COFs obtained by post-synthesis modification tend to exhibit high crystallinities and porosities, thereby rendering them suitable materials for use in the fields of chiral resolution, asymmetric catalysis, and chromatography. In this work, TpPa-NO2 was synthesized from 1,3,5-tricarbaldehyde phloroglucinol and 2-nitro-1,4-phenylenediamine, which was then reduced to TpPa-NH2. Subsequently, this material was modified with D-glucose via a post-synthesis modification strategy to obtain the TpPa-NH2-Glu. TpPa-NH2-Glu were characterized by nuclear magnetic resonance (NMR) spectroscopy, Fourier transform-infrared (FT-IR) spectroscopy, X-ray powder diffraction (XRD) analysis, etc. In the XRD pattern, the peaks observed at 4.7°, 8.1°, 11.1°, and 27° were attributed to the TpPa-NH2-Glu, and these peaks are consistent with previous reports, thereby confirming the successful synthesis of this derivative. In addition, circular dichroism experiments indicated that the TpPa-NH2-Glu exhibited a Cotton effect, further confirming the chiral COF was prepared. Subsequently, this material was immobilized on the surface of spherical silica gel particles via the net-wrapping method to prepare a stationary phase for high performance liquid chromatographic column. Using n-hexane-isopropanol (9∶1, v/v) or methanol-water (9∶1, v/v) as mobile phases at a flow rate of 0.5 mL/min, 16 racemates and two benzene-based positional isomers (o,m,p-nitroaniline and o,m,p-Iodoaniline) were successfully resolved by this chiral column. In addition, under methanol-water (9∶1, v/v) mobile phase conditions, five racemates were separated, among which propranolol hydrochloride, warfarin, and metoprolol reached baseline separation. Furthermore, under n-hexane-isopropanol (9∶1, v/v) mobile phase conditions, 11 racemates were resolved, among which ethyl 2-bromopropionate and 3-butyn-2-ol reached baseline separation. Meanwhile, the effect of temperature on the TpPa-NH2-Glu liquid chromatography column and the repeatability of the TpPa-NH2-Glu liquid chromatography column were also explored. The HPLC column prepared by TpPa-NH2-Glu had good repeatability, and its relative standard deviation (RSD) was 1.55% and 1.46%, respectively. It is demonstrated that the TpPa-NH2-Glu material has good resolution ability for chiral compounds.
More Related Videos
09:34Improved Polymerase Chain Reaction-restriction Fragment Length Polymorphism Genotyping of Toxic Pufferfish by Liquid Chromatography/Mass Spectrometry
Published on: September 20, 2016
13:36Simple In-House Ultra-High Performance Capillary Column Manufacturing with the FlashPack Approach
Published on: December 4, 2021
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Thin-Layer Chromatography (TLC): Overview
To begin the analysis, a mixture of compounds is spotted on the starting line on the TLC plate using a thin capillary. The bottom of the...
High-Performance Liquid Chromatography: Elution Process
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Instrumentation
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...