Related Experiment Video
Updated: Aug 12, 2025

Asthma Detection Research Based on Voice Signal Processing and Machine Learning
Published on: July 22, 2025
A Novel Pulse-Taking Device for Persian Medicine Based on Convolutional Neural Networks
Vahid Reza Nafisi1, Roshanak Ghods2, Seyed Vahab Shojaedini1
1Biomedical Engineering Group, Electrical and Information Technology Department, Iranian Research Organization for Science and Technology, Tehran, Iran.
Background:
In Persian medicine (PM), measuring the wrist pulse is one of the main methods for determining a person's health status and temperament. One problem that can arise is the dependence of the diagnosis on the physician's interpretation of pulse wave features. Perhaps, this is one reason why this method has yet to be combined with modern medical methods. This paper addresses this concern and outlines a system for measuring pulse signals based on PM.
Methods:
A system that uses data from a customized device that logs the pulse wave on the wrist was designed and clinically implemented based on PM. Seven convolutional neural networks (CNNs) have been used for classification.
Results:
The pulse wave features of 34 participants were assessed by a specialist based on PM principles. Pulse taking was done on the wrist in the supine position (named Malmas in PM) under the supervision of the physician. Seven CNNs were implemented for each participant's pulse characteristic (pace, rate, vessel elasticity, strength, width, length, and height) assessment, and then, each participant was classified into three classes.
Conclusion:
It appears that the design and construction of a customized device combined with the deep learning algorithm can measure the pulse wave features according to PM and it can increase the reliability and repeatability of the diagnostic results based on PM.
More Related Videos
04:51Pupillary Response as Assessment of Effective Seizure Induction by Electroconvulsive Therapy
Published on: April 11, 2019
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Special considerations while measuring pulse
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Pulse Assessment Sites
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps: