Related Experiment Video
Updated: Aug 12, 2025

Synovial Fluid Analysis to Identify Osteoarthritis
Published on: October 20, 2022
Nationwide Results of Microorganism Antigen Testing as a Component of Preoperative Synovial Fluid Analysis
Krista O'Shaughnessey Toler1, Pearl Ravindra Paranjape1, Alex McLaren2
1Department of Diagnostics Research and Development, Zimmer Biomet, Warsaw, Indiana.
Background:
Antigen immunoassays to detect synovial fluid (SF) microorganisms have recently been made available for clinical use. The purpose of this study was to determine the sensitivity and specificity of an SF microorganism antigen immunoassay detection (MID) panel, evaluate the panel's capability to detect microorganisms in the setting of culture-negative periprosthetic joint infection (PJI), and determine diagnostic predictive values of the MID panel for PJI.
Methods:
This study included 67,441 SF samples obtained from a hip or knee arthroplasty, from 2,365 institutions across the United States, submitted to 1 laboratory for diagnostic testing. All data were prospectively compiled and then were analyzed retrospectively. Preoperative SF data were used to classify each specimen by the International Consensus Meeting (2018 ICM) definition of PJI: 49,991 were not infected, 5,071 were inconclusive, and 12,379 were infected. The MID panel, including immunoassay tests to detect Staphylococcus, Candida, and Enterococcus, was evaluated to determine its diagnostic performance.
Results:
The MID panel demonstrated a sensitivity of 94.2% for infected samples that yielded positive cultures for target microorganisms (Staphylococcus, Candida, or Enterococcus). Among infected samples yielding positive cultures for their respective microorganism, individual immunoassay test sensitivity was 93.0% for Staphylococcus, 92.3% for Candida, and 97.2% for Enterococcus. The specificity of the MID panel for samples that were not infected was 98.4%, yielding a false-positive rate of 1.6%. The MID panel detected microorganisms among 49.3% of SF culture-negative infected samples. For PJI as a diagnosis, the positive predictive value of the MID panel was 91.7% and the negative predictive value was 93.8%. Among MID-positive PJIs, 16.2% yielded a discordant cultured organism instead of that detected by the antigen test.
Conclusions:
SF microorganism antigen testing provides a timely adjunct method to detect microorganisms in the preoperative SF aspirate, yielding a low false-positive rate and enabling the detection of a microorganism in nearly one-half of SF culture-negative PJIs.
Level Of Evidence:
Prognostic Level II . See Instructions for Authors for a complete description of levels of evidence.
Related Concept Videos
Urine Studies II: Urine Culture and Sensitivity Test
Sputum Studies I: Gram Stain, cytology, and Acid-fast smear and culture
Gram Stain
The Gram Stain is an integral part of sputum studies. It involves the staining of sputum, which permits...
Sputum Studies II: Culture and Sensitivity
Sputum culture and sensitivity is a medical procedure used to diagnose bacterial infections in the respiratory tract and select the most appropriate antibiotics for treatment. This process involves analyzing sputum samples of thick and opaque secretions produced in the lungs and airways. These samples are collected from patients and then sent to the laboratory for analysis.
The test can identify various pathogens responsible for respiratory infections, including Streptococcus,...