Related Experiment Video
Updated: Aug 12, 2025

A Novel Digital Platform for a Monitored Home-based Cardiac Rehabilitation Program
Published on: April 19, 2019
Prospective Validation of 2B-Cool : Integrating Wearables and Individualized Predictive Analytics to Reduce Heat
Srinivas Laxminarayan, Samantha Hornby, Luke N Belval1
1Korey Stringer Institute, University of Connecticut, Storrs, CT.
Introduction:
An uncontrollably rising core body temperature (T C ) is an indicator of an impending exertional heat illness. However, measuring T C invasively in field settings is challenging. By contrast, wearable sensors combined with machine-learning algorithms can continuously monitor T C nonintrusively. Here, we prospectively validated 2B-Cool , a hardware/software system that automatically learns how individuals respond to heat stress and provides individualized estimates of T C , 20-min ahead predictions, and early warning of a rising T C .
Methods:
We performed a crossover heat stress study in an environmental chamber, involving 11 men and 11 women (mean ± SD age = 20 ± 2 yr) who performed three bouts of varying physical activities on a treadmill over a 7.5-h trial, each under four different clothing and environmental conditions. Subjects wore the 2B-Cool system, consisting of a smartwatch, which collected vital signs, and a paired smartphone, which housed machine-learning algorithms and used the vital sign data to make individualized real-time forecasts. Subjects also wore a chest strap heart rate sensor and a rectal probe for comparison purposes.
Results:
We observed very good agreement between the 2B-Cool forecasts and the measured T C , with a mean bias of 0.16°C for T C estimates and nearly 75% of measurements falling within the 95% prediction intervals of ±0.62°C for the 20-min predictions. The early-warning system results for a 38.50°C threshold yielded a 98% sensitivity, an 81% specificity, a prediction horizon of 35 min, and a false alarm rate of 0.12 events per hour. We observed no sex differences in the measured or predicted peak T C .
Conclusion:
2B-Cool provides early warning of a rising T C with a sufficient lead time to enable clinical interventions and to help reduce the risk of exertional heat illness.
More Related Videos
10:45A Community-based Stress Management Program: Using Wearable Devices to Assess Whole Body Physiological Responses in Non-laboratory Settings
Published on: January 22, 2018
05:51Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
Related Concept Videos
Decreased Body Temperature
Responses to Heat and Cold Stress
Quantifying Heat
Burn Injuries
The damage results in the death of skin cells, which can lead to a massive loss of fluid. Dehydration, electrolyte imbalance, and renal and circulatory failure follow, which can be fatal. Burn patients are treated with intravenous fluids to offset...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...