Related Experiment Video
Updated: Aug 11, 2025

Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
Intermediate Follow-Up of Balloon-Expandable Versus Self-Expanding Transcatheter Aortic Valve Implantation in
Wassim Mosleh1, Sarfaraz Memon2, Nicole E Hoover2
1Department of Cardiology, Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire.
Abstract:
The clinical impact of prosthesis-patient mismatch (PPM) in patients with small aortic annuli who underwent transcatheter aortic valve (AV) implantation with either balloon-expandable (BE) or self-expanding (SE) valves remains controversial. We assessed in-hospital and intermediate clinical outcomes in 573 patients with transfemoral transcatheter AV implantation with a small AV annulus, defined as an AV annulus area ≤430 mm2. A total of 337 patients treated with a 23-mm BE valve (SAPIEN 3, Ultra) were compared with 236 patients treated with a 26-mm SE valve (Evolut series). Valve-in-valve cases were excluded, and late echo follow-up (mean 674 ± 438 days) was assessed in a subset of 292 patients (51.0%). Well-matched BE and SE cohorts did not differ with respect to major in-hospital outcomes, other than a borderline increase in vascular complications and composite bleeding in patients with SE. Patients with BE had a higher incidence of severe PPM on discharge echocardiography (16.9% vs 6.8%, p <0.002). The mean AV gradient at 30 days was higher for patients with BE (12.2 ± 4.2 vs 6.2 ± 7.9 mm Hg, p <0.001) and at late follow-up (14.0 ± 8.2 vs 7.2 ± 3.5 mm Hg, p <0.001). The follow-up left ventricular ejection fraction and incidence of >mild aortic insufficiency were similar. All-cause mortality for the 2 cohorts was similar, with an overall mean (95% confidence interval) survival time of 61.2 months (57.8 to 64.5; p = 0.98). There were no significant survival differences between combined patients with BE and SE with no, moderate, or severe PPM, with an overall mean (95% confidence interval) survival time of 32.5 (30.5 to 34.5) months combining valve types (p = 0.23). In conclusion, despite an increased incidence of PPM with higher mean AV gradients that persist on late echocardiography in the BE cohort, patients with BE and SE with small aortic annuli have similar clinical outcomes at intermediate follow-up. Moderate and severe PPM had no impact on survival at a mean follow-up of 32.5 months.
More Related Videos
14:14Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022